32
Description of functions
Manual mode (strokes/min)
Manual mode
【
Standard (pulse-input) type
】
【
Analog type
】
【
Timer type
】
Manual mode
✽
The parameter settings can be changed using the [
] and [
] keys.
For details on the parameters, refer to the settings list below.
Parameter settings screen
P-2
~
P-9
Parameter settings
Setting flow
List of parameters
NOTE
• A separate signal cable is required in order to use the alarm output.
No.
Item
Description
Parameter
Default
Notes
P-01
SAFE mode
Selects whether to use the
SAFE mode.
0: Disabled
1: Enabled
0: Disabled
Cannot be used by the PW
-200,
boiler type or high-pressure type.
P-02
Pulse overflow error *
1
Selects whether to display and
output an alarm when a pulse
overflow error has occurred.
0: Disabled
1: Enabled
0: Disabled
The setting of this parameter
takes effect only for the PW
and PWT.
P-03
Blocked operation
Selects whether to display and
output an alarm during operation
with the discharge side blocked.
0: Disabled
1: Enabled
0: Disabled
P-04
Level error *
1
Selects whether to display and
output an alarm when a level
error has occurred.
0: Disabled
1: Enabled
0: Disabled
A level error results when a stop
input signal is supplied with ‘enabled’
selected as the parameter’s setting.
P-05
Analog error *
1
Selects whether to display and output an alarm
when the analog input value has dropped below
the lower limit or risen above the upper limit.
0: Disabled
1: Enabled
0: Disabled
The setting of this parameter
takes effect only for the PWM.
P-06
Sensor detection
Diagnoses the sensor status.
—
—
“1” is displayed when normal, and “0”
when abnormal. The ECO mode, SAFE
mode and ALARM functions do not oper-
ate when the sensor status is abnormal.
P-07
Setting of operation to be
performed when the exter-
nal operation and stop
input signals are received
S e l e c t s t h e o p e ra t i o n o f
the pump when an external
operation or stop input signal
is received.
0: Stop
1: Operation
0: Stop
P-08
ECO mode setting
Selects whether to use the
ECO mode.
0: Stop
1: Operation
1: Operation
The initial value for DCLPW
/
CLPW
is ‘disabled.’ Do not set ‘1:
enabled’ for DCLPW
/CLPW
.
P-09
Delay time setting for alarm
Displays the alar ms, and
sets the output delay time.
0 to 600 sec
0 sec.
P-10
Pulse input check
Checks whether pulses have
been input.
—
—
“1” is displayed when pulse input is
ON, and “0” when pulse input is OFF.
The setting of this parameter takes
effect only for the PW and PWT.
*1 Refer to the alarm codes.
✽
For details on how to change the operation mode, refer to the setting flow at the end of this manual.