6
Performance Checks
Test Procedures
6-11
Trigger operation
Characteristics
This tests the operation of the trigger circuit. It includes tests for the
triggered, gated and counted bursts run modes. It also tests the
operation of the trigger advance options, the delayed trigger and re-
trigger functions, as well as the trigger input level and slope sensitivity.
The run modes are common to all channels however, each channel
has its own trigger circuit and therefore, each channel must be tested
separately.
Trigger, Gate, and
Burst
Characteristics
Equipment: Oscilloscope, function generator, counter
Preparation:
1. Configure the Oscilloscope follows:
Termination:
20 dB, 50
Ω
feedthrough attenuator at the
oscilloscope input
Setup:
As required for the test
2. Connect 2074 Channel outputs to the oscilloscope input
3. Configure the function generator as follows:
Frequency 1
MHz
Run Mode:
As required by the test
Wave:
TTL Square
4. Connect the function generator output to the 2074 TRIG IN
connector
5. Configure the 2074 as follows:
Frequency: 25
MHz
Waveform: Sinewave
Burst Count:
1e6 counts, each channel
Amplitude: 1
V
Trigger Source: External
Output: On
Test Procedure
1. Perform trigger and gate tests using Tables 6-10
2. Configure the counter to TOTB Measurements and perform
burst tests using Tables 6-10. Set counter trigger level to
100mV.
Table
6-10, Trigger, gate, and burst Characteristics.
2074 Run
External Trigger
Oscilloscope Reading
Mode
Pulse
CH1, CH2, CH3, CH4
Pass
Fail
Triggered
1 MHz, Continuous
Triggered waveform
Gated
1 MHz, Continuous
Gated Waveform
Burst
Single shot
Burst, 1e6 waveforms
Содержание 5064
Страница 26: ...1 5 Figure 1 2 ArbConnection The Control Panels Figure 1 3 ArbConnection The Wave Composer...
Страница 71: ...2074 User Manual 2 18 This page intentionally left blank...
Страница 145: ...2074 User Manual 3 74 Figure 3 48 Reading the 2074 Internal Temperature...
Страница 207: ...2074 User Manual 4 62 Figure 4 47 Complete Pulse Train Design Figure 4 48 Section 5 of the Pulse Train Design...
Страница 220: ...4 ArbConnection Logging SCPI Commands 4 75 Figure 4 58 Log File Example...
Страница 221: ...2074 User Manual 4 76 This page was intentionally left blank...
Страница 333: ...2074 User Manual 7 2...
Страница 358: ...7 Adjustments and Firmware Update Updating 2074 Firmware 7 27 Figure 7 9 Firmware Update Completed...
Страница 359: ...2074 User Manual 7 28 This page was intentionally left blank...
Страница 360: ...Appendices Appendix Title Page A Specifications A 1 1...
Страница 361: ...2074 User Manual 2...