Taber 710 Скачать руководство пользователя страница 7

Spline Shaft Finger - Adjustment

The following procedure describes the correct
way to adjust the spline-shaft fingers.

1. Using hex wrench supplied, loosen set screw

and remove weight from spline-shaft finger.

2. If upper bearing (#5) is assembled tightly in

gantry and locked with bottom set screw (#4),
continue with step 3.  Otherwise,

a.

Remove spline shaft (#1) from bearing
assembly.

b.

Hand-tighten upper bearing (#5) and
lock with bottom set screw (#4A).

c.

Adjust lower bearing (#2) into beam until
shoulder of bearing is in contact with gantry.

d.

Slide spline shaft (#1) into upper bearing
until shaft stops against lower bearing.
Lightly twist lower bearing clockwise until
spline grooves align into lower bearing
and slide freely.

3. Loosen two adjustment set screws (#4B & C)

approximately ½ to ¾ turn.

4. Apply light tension between spline shaft and

lower bearing by slightly twisting lower bear-
ing counter-clockwise.

5. Using hex wrench, apply a light tightening force

to top set screw (#4B) locking lower bearing
into place.  WARNING,  DO NOT OVER
TIGHTEN SET SCREW
.  Spline shaft will no
longer move freely through bearings.

6. Tighten set screw (#4C) on the opposite side

of the gantry until spline shaft moves freely.

7. Re-attach weight and tighten set screws.

Load on Specimen Surface

To check the loading forces, measure directly
under the scratch (mar) tip, using a spring bal-
ance or equivalent.  If necessary, adjust the
weight(s) to meet the required scratch force(s) on
the surface of the sample.

Lubricator / Regulator

The maximum inlet pressures and temperatures
are as follows:

150 psig (10.3 bar)
125° F (51.7° C)

Given normal operating conditions this unit will
be trouble-free.  It is recommended that you serv-
ice the unit at least every six months.  

CLEANING:

To clean bowl assembly:

a. Depressurize unit.

b. Remove bowl and bowl guard assembly by

turning counterclockwise.

c. Inspect bowl daily for damaged or deteriorat-

ed seals. Replace with original manufacturers
approved seals and bowls.

d. If bowl becomes dirty, replace it or clean it by

wiping the bowl with a soft dry cloth or a mild
detergent.

e. Before returning to service, ensure that all

seals have been reinstalled or replaced.

6

710 Operating Instructions ver 1.1

Содержание 710

Страница 1: ...INDUSTRIES 9001 2000 ISO CERTIFIED Multi Finger Scratch Mar Tester Model 710 Operating Instructions ...

Страница 2: ...r Industries reserves the right to make changes without notice at any time in colors material specifications and models and to dis continue models CLAIMS FOR SHORTAGES We use extreme care in selection checking and packing to eliminate the possibility of error If a shipping error is discovered 1 Carefully examine the packing materials and ensure nothing was inadvertently overlooked when the shipmen...

Страница 3: ...aft fingers into the guide bearings by matching the pattern on the shaft and bearing Each bearing has been pre adjusted at the factory If a shaft DOES NOT slide easily through the bearings see MAINTE NANCE Spline Shaft Finger Adjustment INTRODUCTION The Taber Multi Finger Scratch Mar Tester is used to measure the relative resistance or sus ceptibility of a material surface to scratching marring go...

Страница 4: ... parts smaller or slightly contoured samples may be used To test specimens that exceed the 22mm thick ness spacer blocks may be inserted into the support arms of the gantry OPERATING PROCEDURES Prior to testing it is recommended that all sam ples be preconditioned in a controlled atmos phere such as 23 2 C and 50 5 relative humidity for not less than 24 hours Samples should be tested under the sam...

Страница 5: ...ening the lock thumbnut Lower the scratch mar tips onto a dummy test specimen and verify the speed adjustment To calculate the platform speed divide 100mm by the time shown on the display X WARNING It is possible for the speed of the platform to exceed the capacity of the automatic Start Stop of the electronic timer Should this occur disconnect the timer and operate electronic timer by hand using ...

Страница 6: ...gth of time between scratch and evaluation Plastics The properties of plastic materials can greatly influence the evaluation of scratch and mar resistance It is important to be aware of the fol lowing factors and take them into consideration 1 Many plastics have elastic recovery upon removal of applied stress 2 Many plastics have visco elastic properties and the stresses in the plastics may relax ...

Страница 7: ...place WARNING DO NOT OVER TIGHTEN SET SCREW Spline shaft will no longer move freely through bearings 6 Tighten set screw 4C on the opposite side of the gantry until spline shaft moves freely 7 Re attach weight and tighten set screws Load on Specimen Surface To check the loading forces measure directly under the scratch mar tip using a spring bal ance or equivalent If necessary adjust the weight s ...

Страница 8: ...y and turn clockwise to securely lock in place Reinstall the fill plug The unit is ready for use ADJUSTING DELIVERY RATE The oil delivery rate will change automatically to deliver more oil during increase airflow demand and less oil for airflow lower than the original setting To adjust and set oil delivery rate the unit must be pressur ized and flowing air Turn the transparent sight dome counter c...

Страница 9: ...al Diamond Tool with 90 3 mil 0 003 139 55 121006 Conical Diamond Tool with 90 3 5 mil 0 0035 139 56 121006 1 Precision Weight Kit Used to achieve 0 6N 132740 Optional Weight Set 8N 13N 18N 132401 Optional Weight 25N 132352 5 Standard Specimen Hold Down Clamp Kit each 132455 Oversized EZY Specimen Hold Down Clamp each 132399 Specimen Platform Protective Guard Replacement 132451 3 32 Hex Wrench Rep...

Страница 10: ...NOTES ...

Отзывы: