![Tab T6-Pro Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/tab/t6-pro/t6-pro_product-user-manual_3125935016.webp)
Failure Recovery
14
Common failure
Possible reason
Solution
Main unit does not work
Handle not installed in place
Please reinstall to ensure that it is in
place before use
The main unit has no power or insufficient
power
Please fully charge the main unit
before using it
The rolling brush is not installed in place/the
rolling brush is entangled with hair and stops
rotating
Reinstall or clean the rolling brush
Dirty-water tank is not installed in place
Reinstall the dirty-water tank
Dirty-water tank is full
Dump the dirty water in the
dirty-water tank before use
Machine suction is
weakened
Filter element blockage
Please clean the filter element
Rolling brush cover, filter element and
clean-water tank are not installed in place.
Confirm whether it is installed in
place before use
The rolling brush is entangled with hair
Remove the winding of the rolling
brush before use
Foreign matter or blockage in the pipeline
Please clean the pipeline
There is abnormal noise in
motor operation
Excessive dirty water in the dirty-water tank
Dump the dirty water in the
dirty-water tank before use
The suction port is blocked
Clear the obstacles in the suction port
When charging, the screen
power prompt icon is not
displayed
The power adapter is not connected to a
power socket
Check whether the power adapter is
plugged in
The connection between the power adapter
and the charging base is not in place
Check whether it is in good
connection
The docking between the main unit and the
charging base is not in place
Please confirm that the main unit is
placed correctly
No water from the main
unit
Clean-water tank is not installed in
place/clean-water tank is short of water
Reinstall or add water to the
clean-water tank
Water leakage from air
outlet
The filter element is not dried after cleaning After cleaning, make sure to dry it
before use
Self-cleaning does not
work
The rolling brush may get stuck by large
particles
Open the rolling brush cover for
inspection and cleaning
The machine is not charging
Ensure that the main unit starts the
self-cleaning function again when it
is in the charging state
The power of the machine is less than
10% and cannot start self-cleaning
In the charging state, start the
self-cleaning function when the
power is greater than 10%
Dirty-water tank is not installed in
place/dirty-water tank is full of water
Reinstall or dispose of the dirty-water
tank