background image

f. 

Internal communication error: Check the internal communication wiring connection 
whether is wrong or missing, then make a restart of the whole system.

g. 

Critical Failure: Both RED and YELLOW LEDs constant lighting.
Solution: Contact the distributor, need a replacement or repairment.

Excluding the four points above, if the faulty is still cannot be located, record the failure 
description and LEDs status, turn off power switch of the battery and contact the distribu-
tor.

6. Emergency Situations

1. 

Leaking Batteries

If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is 
exposed to the leaked substance, immediately perform the actions described below.

Inhalation:

 Evacuate the contaminated area, and seek medical attention.

Contact with eyes:

 Rinse eyes with flowing water for 15 minutes, and seek medical at

-

tention.

Contact with skin:

 Wash the affected area thoroughly with soap and water, and seek 

medical attention.

Ingestion:

 Induce vomiting, and seek medical attention.

2. 

Fire

NO WATER! Only dry powder fire or carbon dioxide extinguisher can be used; if possible, 
move the battery pack to a safe area before it catches fire.

3. 

Wet Batteries

If the battery pack is wet or submerged in water, do not let people access it, and then 
contact TAB or an authorized dealer for technical support.

4. 

Damaged Batteries

Damaged batteries are dangerous and must be handled with the utmost care. They are 

not fit for use and may pose a danger to people or property. If the battery pack seems to 

be damaged, pack it in its original container, and then return it to TAB or an authorized 
dealer.

NOTE 

Damaged batteries may leak electrolyte or produce flammable gas.

In case a damaged battery needs recycling, it shall follow the local recycling regulation (ie. 
Regulation (EC) Nº 1013/2006 among European Union) to process, and using the best 

available techniques to achieve a relevant recycling efficiency.

Any further questions, please contact TAB: [email protected]

21

R2428_Operating_Manual_13.05.2021.indd   21

R2428_Operating_Manual_13.05.2021.indd   21

17.5.2021   11:35:50

17.5.2021   11:35:50

Содержание R2428

Страница 1: ...www tab si Lithium Ion Phosphate Energy Storage System R2428 Operation Manual R2428_Operating_Manual_13 05 2021 indd 1 R2428_Operating_Manual_13 05 2021 indd 1 17 5 2021 11 35 42 17 5 2021 11 35 42...

Страница 2: ...R2428_Operating_Manual_13 05 2021 indd 2 R2428_Operating_Manual_13 05 2021 indd 2 17 5 2021 11 35 42 17 5 2021 11 35 42...

Страница 3: ...3 1 Schematic Diagram of Solution 12 3 2 Explanation of Symbol 13 3 3 Tools 13 3 4 Safety Gear 14 4 Installation 14 4 1 Package Items 14 4 2 Installation Location 16 5 Trouble Shooting Steps 20 5 1 Pr...

Страница 4: ...uchable area Warning electric shock Warning Fire Do not place near flammable material Read the product and operation manual before operating the battery system Grounding Recycle label The certificate...

Страница 5: ...ething abnormal 7 Do not use cleaning solvents to clean battery 8 Do not expose battery to flammable or harsh chemicals or vapors 9 Do not paint any part of battery include any internal or external co...

Страница 6: ...t is prohibited to connect the battery with different type of battery 3 It is prohibited to put the batteries working with faulty or incompatible inverter 4 It is prohibited to disassemble the battery...

Страница 7: ...environmentally friendly Cathode material is made from LiFePO4 with safety performance and long cycle life Battery management system BMS has protection functions including over dis charge over charge...

Страница 8: ...ischarge Current A 85 Peak Charge Discharge Current A 100A 15sec Communication RS485 CAN Configuration max in 1 battery group 20pcs Working Temperature 0 C 55 C Charge 10 C 55 C Discharge Shelf Temper...

Страница 9: ...ail Please check below table LED Indicators Instructions for the detailed definition Protection Protection light RED LED to show the battery is under BMS protection Combine with SOC LEDs to show which...

Страница 10: ...age Discharge MOS OFF Possible reason discharging over current Low Voltage Short circuit Reverse polarity Charge and discharge MOS all OFF Possible reason Over Low Temperature MOS Over Temperature BMS...

Страница 11: ...Terminal RJ45 port follow TAB Low voltage CANBUS protocol for communication between master battery and host equipment Definition of RJ45 Port Pin No RS485 Pin CAN Pin 1 2 GND 3 4 CAN H 5 CAN L 6 7 RS...

Страница 12: ...power plug BMS function Protection and Alarm Management and Monitor Charge Discharge Cut off Cells Balance Charge Over Voltage Intelligent Charge Model Discharge Under Voltage Capacity Retention Calc...

Страница 13: ...Use properly insulated tools to prevent accidental electric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their ti...

Страница 14: ...n 4 1 Package Items Unpacking and check the Packing List 1 For battery module package Two power cables and one communication cable for each battery package Grounding cable Grounding cables use 10AWG y...

Страница 15: ...modules 2 For battery system connects to inverter Two long power cables max current capacity 120A and one communication cable for each energy storage system NOTE These three long cables are NOT in bat...

Страница 16: ...d humidity are maintained at a constant level There is minimal dust and dirt in the area CAUTION If the ambient temperature is out of the operating range the battery pack stops operating to protect it...

Страница 17: ...he cabinet follow below picture 2 Fix each module with the cabinet with 4 screws 3 Connect the cables between battery modules including grounding cables follow below picture 17 R2428_Operating_Manual_...

Страница 18: ...power cable connect as A D or B C donot connect as A B or C D to avoid unbalancing current transmitted For 2 pairs of external power cable connect as A D and B C For more than 2 pairs of external cab...

Страница 19: ...er Battery Module others are slaves 1 master battery configure with maximum 19 slave batteries 4 Press the Start Button SW of master battery to power on all the battery LED light will be on after mast...

Страница 20: ...e LED Indicators Instructions to check a Over Low temperature Above 55 C or under 10 C the battery could not work Solution turn off the battery module move battery to the normal operating tem perature...

Страница 21: ...on Ingestion Induce vomiting and seek medical attention 2 Fire NO WATER Only dry powder fire or carbon dioxide extinguisher can be used if possible move the battery pack to a safe area before it catch...

Страница 22: ...R2428_Operating_Manual_13 05 2021 indd 22 R2428_Operating_Manual_13 05 2021 indd 22 17 5 2021 11 35 50 17 5 2021 11 35 50...

Страница 23: ...R2428_Operating_Manual_13 05 2021 indd 23 R2428_Operating_Manual_13 05 2021 indd 23 17 5 2021 11 35 50 17 5 2021 11 35 50...

Страница 24: ...a Slovenia Tel 386 2 87 02 300 Web www tab si E mail info tab si P U R E E N E R G Y M A X I M U M P O W E R R2428_Operating_Manual_13 05 2021 indd 24 R2428_Operating_Manual_13 05 2021 indd 24 17 5 20...

Отзывы: