25
Tips on troubleshooting
The following troubleshooting approaches may help in the event of faulty operation, but before work
-
ing on the freshwater module, it is always important to ensure that it is at zero volt and that no hot
pipe temperatures can occur.
Other possible solutions:
• Check temperature sensors (sensors and wiring)
• Check cable connection between controller and flow sensor
• Check water pressure on secondary side
• Check flow sensor for contamination
• Check position of set value adjuster (may be twisted by 180°)
Subject to technical modifications as well as typographical and printing errors. This manual is only
valid for devices with the corresponding firmware version. Our products are subject to constant tech
-
nical advancement and further development. We therefore reserve the right to make changes without
prior notice.
©
Status LED illuminated?
Check power supply,
check circuit breaker,
check connecting cable
and clamping
See table „LED status
Is the pump running in manual
mode?
Check pump cable (pow
-
er supply and PWM) at
pump and terminal,
check pump for seizing
(corrosion), check valve.
Is DHW available after
manual mode?
Check flow switch cable
Vent primary side,
check valves
Not illuminated
illuminated/fla
shing differen
tly
Illuminated green
Running
DHW not avail.
Does not run/move
DHW avail.
Содержание FRISTAR3
Страница 1: ...ta co at FRISTAR3 FRESH WATER STATION Operating manual English Manual Version 1 05 ...
Страница 2: ......
Страница 8: ...8 Dimensions Housing dimensions thermal insulation cover W x H x D 366 x 573 x 160 mm ...
Страница 27: ......