TA-CMI is a computer programmed measuring instrument. It is a handheld instrument for
measuring differential pressure, temperature, and flow through balancing valves in hydronic
systems. It consists of a sensor unit and a instrument unit that has been programmed with the
TA valve characteristics, which makes it possible to take a direct reading of flow and differen-
tial pressures.

The TA-CMI has two main components:

• A sensor unit which contains a piezoresistive pressure sensor, one measurement valve,

connections and rechargeable NiMH batteries. The measurement valve has a safety function
which protects the sensor from too high differential pressures.

• An instrument unit which contains a micro computer, input touch pad, LCD display and

rechargeable NiMH batteries.

The instrument and the sensor units communicate wirelessly or by cable.

= Warning – read the manual.

The TA-CMI can be cleansed with a damped cloth and a lenient cleaning-agent.

General

General

Guarantee

TA-CMI is guaranteed to be free of material or performance defects in normal use and service. The
guarantee period is five years, starting from and including the day of delivery. A guarantee period
of 180 days applies for repairs and service.
This guarantee applies only for the original purchaser and does not include consumable materials
or measuring instruments which, in TA´s opinion, have been used incorrectly, have been neglected
or have been damaged as a result of accident or abnormal use or handling.
Tour & Andersson AB guarantees that its software operates in all significant respects in accordance
with its performance specification. TA does not guarantee that its software is fault-free or that it will
operate without crashing.
TA´s obligations in respect of its guarantee are restricted to full replacement of the purchase cost or
cost-free repair or replacement of defective products delivered to a Tour&Andersson AB authorised
service centre during the guarantee period, at Tour&Andersson AB's discretion. To claim service
under guarantee, either contact the nearest TA authorised service centre or send the product,
carriage-paid (FOB) and insured, to the nearest Tour & Andersson AB authorised service centre with
a description of the problem. TA does not accept the risk of damage to the product during transport.
After repair under guarantee, the product will be returned carriage-paid (FOB) to the purchaser.
If TA is of the opinion that the fault has been caused by incorrect use, modifications, accident or
abnormal use or handling, we will submit an estimate for the cost of repairs and await approval of
this estimate before starting work. After repair, the product will be returned carriage-paid to the
customer, after which the customer will be invoiced for the cost of repair and of returning the
product (FOB).

Note!

 If the warranty seal is broken or tampered with, this guarantee is null and void.

Guarantee

FCC Notification and ETL markings

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

Caution: 

Changes or modifications of the equipment, not expressly approved by the party

responsible for compliance, could void the user´s authority to operate the equipment.

NOTE: 

This equipment has been tested and found to comply with the limits for a Class B digital

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protections against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.

ETL LISTED: 

Conforms to UL std. 61010B-1: Certified to CAN/CSA std. C22.2 No.1010.1-92

Содержание CMI

Страница 1: ...TA CMI 307 161 50 2004 xx User Manual...

Страница 2: ...ument 9 Connection to measuring points 10 Disconnection from measuring points 12 Measure Valve 14 Entering the valve factor Kv value for other valve types 18 Define media 20 Freezing measurements 23 M...

Страница 3: ...r AnderssonAB authorised service centre with a description of the problem TA does not accept the risk of damage to the product during transport After repair under guarantee the product will be returne...

Страница 4: ...nter Storage above 40 C reduces battery life Unpacking Check that these items are delivered Unpacking TA CMI Dok nr 01 2003 06 GB Manual 1 SE Manual xx TA CMI 1 2 3 4 5 6 7 8 9 10 11 12 1 Instrument u...

Страница 5: ...shows how you set or determine the number of valve turns on a TA valve The valve s opening position can be read on the digital handwheel Closed valve Valve open to 2 3 turns Keyboard two keys Functio...

Страница 6: ...The main function menu of the TA CMI is displayed You select different functions from the main function menu by pressing the down or up key repeatedly and then pressing Enter on the desired selection...

Страница 7: ...ng points 3 Connectiontomeasuringpoints 2 Connect the measuring needles to the measuring hoses Connection to measuring points 1 Connect the measuring hoses to the sensor unit Note The connections with...

Страница 8: ...ways disconnect the measuring needles from the measuring points 1 before disconnecting the bayonet couplings at the measuring hoses and the sensor unit 2 3 Disconnectionfrommeasuringpoints 1 Disconnec...

Страница 9: ...for STAF 125 this error message is displayed MeasureValve 1 Connect the sensor unit to the measuring points on the valve according to pages 10 11 Risk of burn if the media is hot Always connect the m...

Страница 10: ...ensor unit 11 When the correct valve setting is specified press Done If an error message is displayed press OK The setting is automatically changed to the maximum value possible or if you have tried t...

Страница 11: ...ey then pressing Enter 9 Confirm the entered valve name 4 Enter the appropriate valve factor by using the up and down keys Use the right key to move the cursor to the next digit 5 Confirm 10 After you...

Страница 12: ...pe displayed in the Measure Valve menu does not correspond to actual media type you have to define appropriate media according to below 1 Navigate to the media type line by repeatedly pressing the dow...

Страница 13: ...ethylene glycol or propylene glycol you can stop reading here The appropriate flow value is now displayed If the system contains any other media type enter the density and the viscosity of the media...

Страница 14: ...media for flow calculations see pages 20 21 Save the measured temperature as media temperature according to below 1 In the Measure Temp menu press Functions 2 Select Save as media temp by pressing En...

Страница 15: ...calculation HandwheelSettingcalculation This function is used to calculate the valve setting that corresponds to a given flow and differential pressure for a specific valve The function includes no me...

Страница 16: ...rns is displayed If the pressure value is out of the pressure range 0 5 200 kPa for TA CMI an error message is displayed press OK Finally enter the appropriate differential pressure and press Enter Th...

Страница 17: ...is off until the sensor unit has been connected to the instrument unit via the cable Instrument Setup and Information Information In the Information menu you can access information about The instrume...

Страница 18: ...sensor unit to communicate with your instrument unit Incorrect function If the instrument works incorrectly i e due to static electricity discharge keep the start key depressed and within one second a...

Страница 19: ...on tread 1 2 52 197 303 Connection tread 3 4 52 197 304 TA No Measuringhoses 3 m extension red with shut off valve 52 197 093 3 m extension blue 52 197 094 150 mm with twin needle 52 198 801 Spanners...

Страница 20: ...36 TA CMI...

Страница 21: ...on of Registration Number 2125 and 2125 M Certified by SP Q U A L I T Y AND ENVIRONMENT S Y S T E M TOUR ANDERSSONAB X X Sweden Tour Andersson AB Norra Gubberogatan 32 Box 6281 SE 400 60 G teborg Tel...

Отзывы: