TA CMI-S Скачать руководство пользователя страница 10

EU Declaration of conformity

Document-No. / Date:

TA17021 / 02.02.2017

Company / Manufacturer:

Technische Alternative RT GmbH

Address:

A-3872 Amaliendorf, Langestraße 124

This declaration of conformity is issued under the sole responsibility of the manufacturer.

Product name:

CMI, CMI-S

Product brand:

Technische Alternative RT GmbH

Product description:

Control and Monitoring Interface

The object of the declaration described above is in conformity with Directives:

2014/35/EU

Low voltage standard

2014/30/EU (11/09/2018) Electromagnetic compatibility
2011/65/EU (01/10/2022) RoHS Restriction of the use of certain hazardous substances

Employed standards:

Position of CE - label:

 On packaging, manual and type label

Issuer:

Technische Alternative RT GmbH
A-3872 Amaliendorf, Langestraße 124

This declaration is submitted by

Dipl.-Ing. Andreas Schneider, General manager,
02.02.2017

This declaration certifies the agreement with the named standards, contains however no warranty of character

-

istics.

The security advices of included product documents are to be considered.

EN 60730-1: 2011

Automatic  electrical  controls  for  household  and  similar  use  –  Part  1:  General

requirements

EN 61000-6-3: 2007

Electromagnetic  compatibility  (EMC)  -  Part  6-3:  Generic  standards  -  Emission

standard for residential, commercial and light-industrial environments

+A1: 2011

+AC2012

EN 61000-6-2: 2005

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for

industrial environments

EN 50581: 2012

Technical  documentation  for  the  assessment  of  electrical  and  electronic  prod

-

ucts with respect to the restriction of hazardous substances

 

 

Содержание CMI-S

Страница 1: ...ta co at CMI S CONTROL AND MONITORING INTERFACE for switching cabinets Quick guide Mounting and installation Startup guide English Manual Version 1 00 ...

Страница 2: ......

Страница 3: ...ion 1 00 1 Delivery scope 4 2 Mounting and connection 4 2 1 Connections 4 2 2 Making the connections 5 3 IP address 5 3 1 Network with DHCP server standard 5 3 2 Network without DHCP server 5 3 3 Fixed IP address 5 4 Access via browser 5 4 1 Access via LAN or port forwarding 5 4 2 Access via CMI web portal https cmi ta co at 6 5 Resetting and loading of factory settings 8 6 CMI App 9 ...

Страница 4: ...e plug for the CAN bus 1 pc quick guide 2 Mounting and connection The C M I can be mounted on a top hat rail TS35 to EN 50022 standard Measurements 2 1 Connections Connections are labelled and must not be confused Power consumption typ 1 5W Width 22 mm 1 5 HP Micro SD card slot Ethernet port CAN bus CAN bus termination ...

Страница 5: ... 8 encoding in the root directory of the SD card The content of this must be only and IP address example 192 168 0 10 2 Insert the SD card into the CMI S 3 During the next start the CMI S adopts this IP address and deletes the txt file on the SD card The network settings must then be configures locally CMI S menu Settings Ethernet The fixed IP address can only be removed via a reset to factory set...

Страница 6: ...he online manual help ta co at 4 2 Access via CMI web portal https cmi ta co at For access via internet the CMI can be connected to the CMI web portal The web portal is a server set up by the Technische Alternative company 1 Visit the address https cmi ta co at and click Log in or Registration 2 Fill out the registration form and accept the terms of use 3 After completing registration an e mail wi...

Страница 7: ...7 4 After clicking the link the landing page of the web portal will be displayed 5 Add the CMI to the web portal Click the tab Overview 6 Click Add CMI 7 Enter the CMI s data ...

Страница 8: ... loading of factory settings Briefly pressing the reset key on the rear of the CMI restarts the CMI The CMI can also be restarted rest by unplugging the CAN bus connection power supply and plug ging it back in If the reset button is pressed and released while the red LEDs are still illuminated the device is reset to factory settings Caution Holding down the reset button until the red LEDs are no l...

Страница 9: ...access via PC Android iOS Subject to technical modifications as well as typographical and printing errors This manual is only valid for devices with the corresponding firmware version Our products are subject to constant tech nical advancement and further development We therefore reserve the right to make changes without prior notice 2023 ...

Страница 10: ... Issuer Technische Alternative RT GmbH A 3872 Amaliendorf Langestraße 124 This declaration is submitted by Dipl Ing Andreas Schneider General manager 02 02 2017 This declaration certifies the agreement with the named standards contains however no warranty of character istics The security advices of included product documents are to be considered EN 60730 1 2011 Automatic electrical controls for ho...

Страница 11: ......

Страница 12: ...d installation instructions or incorrect maintenance 4 The warranty claim will expire if repairs or actions are carried out by persons who are not authorised to do so or have not been so authorised by us or if our devices are operated with spare supplementary or accessory parts which are not considered to be original parts 5 The defective parts must be sent to our factory with an enclosed copy of ...

Отзывы: