PLUMBING CONNECTIONS
1. A discharge pump system connected to an existing sink drain or floor drain can
pump up to 7ft high but will increase draining time. Drain connections at the rear
of the unit
by ¾” fitting.
2. Gravity drain uses a standard gravity drain. A Floor drain is recommended. P-
Trap is not installed nor supplied. The Floor drain should already have a P-Trap
and UPC codes. DO NOT allow double P-Trap in the system.
3. Hot and Cold-
water supply connections are located at the rear of the unit (½”
fitting). Please be advised that the Hot and Cold-water supply lines are not fitted
with optional backflow. Preventers unless ordered at initial sale.
4. Have a qualified licensed electrician to install the wiring according to local codes.
The Clean jets are 1/18 HP, 120V A.C., 0.55 AMP, 60 Hz. GFI protected circuit
must be used to supply power to the unit. The roller back massage chair uses a
115V A.C. supply.
5. Spa base should be anchored securely to the floor. The base may be anchored
through the opening in the back of the base wherever access is convenient for
the installer.
6. Handheld sprayer. It has complied with applicable requirements of ASME
A112.18.1-2005/CSA B125.1-05
FAILURE TO ANCHOR THE BASE MAY RESULT IN PERSONAL INJURY OR
DAMAGE TO UNIT. DAMAGE AS A RESULT WILL VOID THE WARRANTY.
INSTALLATIONS