background image

5 | 

P a g e

 

SAFETY & PRECAUTION 

 

 

Health Risk Warning 

 

Use of the pedicure spa unit should be pleasant and comfortable; if there is any pain or discomfort, stop use of the 

pedicure spa immediately. 

 

A  physician  should  be  consulted  before  use  of  the  massage  chair  by  anyone  with  the  following 
conditions: Malignant tumor, heart disease, pregnancy, Conditions requiring rest, and back disease or 
trouble from an injury or  accident. 

 

A physician should be consulted before use of the spa basin and jets by anyone with diabetes, swelling, fracture, or 
persistent pain. 

 

Anyone with inflamed legs or feet, open wounds, or fungal infections should not use the spa basin and 
jets. 

 

Misuse or failure to properly clean pedicure spa unit may result in serious health issues, bodily injury, 
and/or death. 

 

 

WARNING - GROUNDING INSTRUCTIONS AND METHODS: 

This unit must be grounded. If it should malfunction or break down, grounding provides a path of least 

resistance for electrical current to reduce the risk of electric shock. All outlets connected to edicures as must 
include a GFCI device (Ground Fault Circuit Interrupter). This will reduce the risk of electric shock. 

 

This unit is for use on a standard 110 Volt 60Hz current. 

 

This unit is equipped with a cord having an equipment grounding conductor and a grounding plug.  The 
plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance 
with all local codes and  ordinances. 

 

If  you  are  in  doubt  as  to  whether  this  unit  is  properly  grounded,  check  with  a  qualified  electrician  or 
serviceman.  Fatal  electric  shock  and  fire  could  occur  with  improper  connection  of  the  equipment- 
grounding conductor. Do not modify the plug provided with the product for any reason; if it will not       fit 
the outlet, have a proper outlet installed by a qualified  electrician. 

 

 

WARNING: THERMAL RESETTING PROTECTION DEVICE 

The massage chair is equipped with a thermal resetting protection device.  This is a safety feature     to 

protect it from overheating. If the chair should  suddenly stop and will not start, turn the main    power 
switch off, and do  not operate the chair for at least 30  minutes. Failure to turn the chair off  may result 
in the chair starting unexpectedly when the device cools. 

Содержание NB-New Beginning

Страница 1: ...1 P a g e T SPA MFG LLC 10510 10520 KINGHURST ST HOUSTON TX 77099 1 888 508 8772 www tspallc com OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE NB New Beginning ...

Страница 2: ...TS CONTENT PAGE SAFETY PRECAUTION 3 SPECIFICATION 6 IDENTIFY YOUR FOOT SPA 7 FOOT SPA CLEARANCE 8 INSTALLATIONS 9 OPERATION USE 14 CLEANING MAINTERNANCE USE 16 WARRANTY SERVICE 17 UL CERTIFICATE 18 WARRANTY REGISTRATION FORM 19 ...

Страница 3: ...nsult a physician before using a hydro massage bathtub equipped with heater WARNING Risk of hyperthermia and possible drowning do not use a hydro massage bathtub equipped with heater immediately following a strenuous exercise WARNING Riskofelectric shock donot permitelectric appliances such as ahair dryer lamp tele phone radio or television within 1 SM 5 feet of this hydro massage bathtub CAUTION ...

Страница 4: ...vent ofapower failure always turn thepower switchtoitsOFFposition Whennotinuse alwaysturn the powerswitchto its OFFposition Todisconnectunit turnallcontrolstoOFFpositionandremovepowercordfromtheoutlet Keepallelectrical devices away from this unit This unit only has a weight capacity of 300pounds 136 06 kg Enter and exit the unit slowly and carefully Never drop or insert any object into any opening...

Страница 5: ...s as must includeaGFCIdevice Ground Fault CircuitInterrupter This will reduce therisk of electric shock This unit is for use on a standard 110 Volt 60Hz current This unit is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If...

Страница 6: ...ity of Tub T 1000 T 1001 4 5 US Gallon Switch On Off Air Activated Switch Power Source Dedicated 15Amp Wall Outlet Require Pipe less whirlpool motor 120 Vac 0 4 Amp 60 Hz Discharge Pump Optional Massage System 115 Vac 3 2 Amp 60Hz 120 Vac 60 Hz Plumbing Source Hot Water Cold Water Drain 3 8 inches 3 8 inches 1 1 4 1 1 2 Warranty Unit Optional Item 1 year 120 Days ...

Страница 7: ...7 P a g e IDENTIFY YOUR FOOT SPA SEAT OPERATION SPA DIMENSION 2 Reclining 25 1 Armrest can be raised up down 3 Chair Sliding 60 26 21 52 ...

Страница 8: ...8 P a g e FOOT SPA CLEARANCE Wall WALL CLEARANCE Wall 22 TYPICAL FOOT SPAS Distance from center drain to the back of the spa 1 23 2 Clearance 21 50 21 ...

Страница 9: ...a g e Align the seat with the pre drilled holes on the base then tightly secure with the nuts and bolts provided Attach trays or remote stand to armrest with screws provided Att IN t STA S LLAT tIO t NtS B ...

Страница 10: ...d by the manufacturer may cause electrical shock or cause injury to person s 7 Never use it outdoors 8 Do not attempt to repair or adjust any electrical or mechanical Cleaning instruction 1 Turn off the unit and wait until the motor is fully stops 2 Hold Hydro whirlpool jet cover firmly and pull to separate from the round magnetic field 3 Turn hydro whirlpool jet cover to left to open and pull out...

Страница 11: ...age jet stream 2 Magnetic whirlpool jet cover can be remove for quick cleaning and sanitizing 3 Built in electronic sensor for pump control 4 AC Whirlpool motor long life 5 Very low power consumption 27W 6 Manufactured in USA Magnet Jet Specifications Model MAGNA JET 120 VAC 60 Hz 1 0 Amp Pump Hydro Massage Dual Jet Flow Mounting single 3 5 hole Diameter Auto tighten Mounting screws 4 ...

Страница 12: ...fitted with optional back flow Preventers unless ordered at initial sale 4 Have a qualified licensed electrician to install the wiring according to local codes The Clean jets are 1 18 HP 120V A C 0 55 AMP 60HZ GFI protected circuit must be used to supply power to the unit The roller back massage chair uses a 115V A C supply 5 Spa base should be anchored securely to the floor The base may be anchor...

Страница 13: ...Typical Discharge Pump Installation OPTIONAL Typical Gravity Sink Direct Drain Installation Backwater Valve Supplied by plumber 3 8 Hot and Cold Hoses 3 8 Hot and Cold Hoses Gravity Sink 2 3 drain pipe to sewer line Drain Elbow ...

Страница 14: ... press discharge pump button to activate 2 minute timer controlled pump Average drain time approximately one minute depending on plumbing characteristics 4 The massage chair s manual book will be send separately Note Read and Follow Chair Manual Instructions Overflow Mixer Discharge Pump Switch OPTIONAL Pump Switch BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING Read and follow...

Страница 15: ...OPERATION USE 15 P a g e IRest SC 135 SC 136 Human Touch 138 ...

Страница 16: ... hot water to just above the jets Add disinfectant Run whirlpool for 15 minutes drain and then wipe dry with clean soft cloth NOTE The use of oil based products can build up in the whirlpool system causing clogging in the jets Adherence to the above cleaning will minimize build up Gulfstream Inc does not recommend the use of mineral oil based products TESTING FLUSHING FOOT SPA After the foot spa h...

Страница 17: ...acement parts during the first 90 days of the stated Warranty Period After 90 days the consumer is responsible for all labor and shipping costs incurred Damage to pump parts and or motor parts due to obstruction in plumbing linesetc Staining fading or discoloration of plastic surfaces due to exposure and or the use of harmful cleaning agents or chemicals Staining fading or discoloration of the sea...

Страница 18: ...18 P a g e ...

Страница 19: ...d date This Limited Warranty is valid if T SPA MFG LLC received registration form SERIAL NO T INVOICE DATE OF PURCHASE YOUR EMAIL ADDRESS FULL NAME SALON NAME SALON ADDRESS CITY STATE ZIP CODE NAME OF DISTRIBUTOR CITY STATE ZIP CODE Completed Warranty Registration Form To T SPA MFG LLC 10510 10520 KINGHURS ST HOUSTON TX 77099 EMAIL info tspallc com LIMITED WARRANTY REGISTRATION FORM ...

Страница 20: ...20 P a g e T SPA MFG LLC 10510 10520 KINGHURST ST HOUSTON TX 77099 1 888 508 8772 www tspallc com ...

Отзывы: