T L Audio EQ-3012 Скачать руководство пользователя страница 4

 

 

INSTALLATION 

 
 

AC Mains Supply. 
 

The unit is fitted with an internationally approved 3 pin IEC connector.  A mating 
socket with power cord is provided with the unit, wired as follows: 
 
 

Brown:   Live. 

 

 

 

Blue:      Neutral. 

 
 

Green/Yellow:  Earth (Ground). 

 
All mains wiring should be performed by a qualified electrician with all power 
switched off, and the earth connection must be used. 
 
Before connecting the unit to the supply, check that the voltage selector switch on the 
rear panel is correctly set.  The unit may be set for 115V (accepting voltages in the 
range 110V to 120V, 60Hz AC), or to 230V (for voltages in the range 220V to 240V,  
50Hz AC). Adjustment to the operating voltage should be made by sliding the selector 
switch left or right with a small screwdriver until the desired voltage is displayed. The 
mains fuse  required is 20mm anti-surge,  1AT  rated at 250V. If it ever necessary to 
replace the fuse, only the same type and rating must be used. The power consumption 
of the equipment is 30VA. 
 

 
Warning:

    attempted operation on the wrong voltage setting, or with an  

 

           incorrect fuse, will invalidate the warranty. 

 

 
Audio Operating Level.

 

 
The equaliser is equipped with inputs and outputs suitable for connection to a wide 
variety of other audio equipment. Generally, the balanced XLR connections will be 
required for interfacing to other professional equipment, where the operating level 
(line-up level or nominal level) will be +4dBu, or about 1.2V rms. The unbalanced 
jack connectors are generally intended for interfacing to semi-professional equipment 
and have an operating level of -10dBu, or about 225mV rms.  
 
The equaliser may be used to change between operating levels, for example by 
connecting the unbalanced output of a semi-pro mixing console to the equaliser’s 
unbalanced input, and taking the balanced output of the equaliser to the balanced input 
of a tape machine at +4dBu. All inputs and outputs of the equaliser may be used 
simultaneously if required. Balanced interconnection is always preferable to obtain the 
best headroom and noise rejection, but can only be used if the other equipment in the 
chain, e.g. the mixing console, also has provision for balanced connections. 

Audio Inputs.

 

Содержание EQ-3012

Страница 1: ...o CRIMSON SERIES User Manual EQ 3012 PARAMETRIC EQUALISER Tony Larking Professional Sales Limited Letchworth England Tel 01462 490600 International 44 1462 490600 Fax 01462 490700 International 44 146...

Страница 2: ...ol calibrated for 0dB nominal gain from the line input sources at the centre and providing 20dB of variation The instrument input has a sensitivity switch associated with it to match the gain to a low...

Страница 3: ...be observed All mains wiring should be installed and checked by a qualified electrician Ensure the correct operating voltage is selected on the rear panel before connecting to the mains supply Never o...

Страница 4: ...attempted operation on the wrong voltage setting or with an incorrect fuse will invalidate the warranty Audio Operating Level The equaliser is equipped with inputs and outputs suitable for connection...

Страница 5: ...linking pins 1 and 3 in the mating XLR connector If this connection is not made a loss in level may result Unbalanced Line Inputs An unbalanced line level input at a nominal level of 10dBu is also pro...

Страница 6: ...a 0 25 mono jack socket Tip Signal Phase or hot Screen Ground Mounting The equaliser may be free standing or mounted in a standard 19 rack Do not locate the unit where it will be subject to external h...

Страница 7: ...ow at a level of 6dBu referred to the balanced output and be fully illuminated at 16dBu where there is still 10dB of output headroom remaining Equalisation Before switching the EQ into circuit it is a...

Страница 8: ...d is also normally operative on channel B covering the mid to upper frequency range of 1KHz to 18KHz Bypass The Equaliser In switch allows the processing to be bypassed for comparison of the equalised...

Страница 9: ...eater than 5Kohm Gain range 20dB to 20dB Nominal input level 10dBu Maximum input level 12dBu 2 pole 0 25 jack socket Auxiliary Input Switchable for high or low gain plus 40dB gain variation Maximum in...

Страница 10: ...nced unbalanced compatible Nominal level 4dBu Output impedance 47 ohms Maximum level 26dBu 3 pin male XLR connector Unbalanced Outputs Output impedance 47 ohms Nominal level 10dBu Maximum level 18dBu...

Страница 11: ...not accept responsibility for damage caused during transportation The equaliser is supported by a limited warranty for a period of one year from the date of purchase During this period any faults due...