t.amp E-1500 Скачать руководство пользователя страница 18

[CLIP]

 | Lights under the following conditions:

n

Channel overload
Reduce in this case the volume until the LED goes out.

n

Output short circuit
Turn off the device immediately, correct the short circuit and turn on the device again.

[PRO]

 | Lights under the following conditions:

n

Three to five seconds after switching on or off when the device is in an unstable condition.

n

The temperature of the amplifier blocks has reached 85°C.

n

One or more protection circuits have been triggered, or the device is faulty.

[POWER]

 | Lights up green when the device is turned on.

In standby mode, the LED lights red. As soon as the unit receives a signal, it switches back to normal mode and the LED

will light up green again.

[PAR]

 | Lights when the device is operated in parallel mode.

[BR]

 | Lights when the device is operated in bridged mode.

3, 4

[CHANNEL A]

[CHANNEL B]

 | Volume control for the respective channel

Connections and operating elements

 

18

E-400, E-800, E-1200, E-1500

Power Amplifier

Содержание E-1500

Страница 1: ...E 400 E 800 E 1200 E 1500 Power Amplifier User Manual...

Страница 2: ...Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 Internet www thomann de 27 03 2023 ID 173888 173889 460282 460283 V4...

Страница 3: ...s and signal words 7 2 Safety instructions 9 3 Features 12 4 Installation and starting up 13 5 Connections and operating elements 17 6 Technical specifications 25 7 Plug and connection assignment 31 8...

Страница 4: ...4 E 400 E 800 E 1200 E 1500 Power Amplifier...

Страница 5: ...e to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We...

Страница 6: ...ion to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please con...

Страница 7: ...bol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided CAUTION This combination of symbol and signal word indicates a pos sible...

Страница 8: ...Warning signs Type of danger Warning high voltage Warning danger zone General information 8 E 400 E 800 E 1200 E 1500 Power Amplifier...

Страница 9: ...ervised or instructed by a person who is responsible for their safety Safety DANGER Danger for children Ensure that plastic bags packaging etc are disposed of properly and are not within reach of babi...

Страница 10: ...the device near any direct heat source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device t...

Страница 11: ...t can interfere with the function of poorly shielded devices The strongest magnetic fields are directly above and below the power amplifier Therefore never place sensitive devices such as pre amplifie...

Страница 12: ...1050 W 4 2 640 W 8 item no 460283 n Inputs XLR phone jack balanced and RCA only for item no 173888 n Outputs Speaker Twist and terminal clamps for speakers n Protection circuits DC short circuit over...

Страница 13: ...t or storage respectively Create all connections while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards...

Страница 14: ...wer amplifier Therefore never place sensitive devices such as pre amplifiers radio transmission systems or tape decks directly above or below the power amplifier When installing the power amplifier in...

Страница 15: ...hannels are internally connected in such a way that twice the output power is available Only the input signal from channel A is amplified and loudspeakers are connected only to the correspondingly mar...

Страница 16: ...their impedance doubles if they are connected in a series their impedance halves if they are connected in parallel For detailed information related to this topic please refer to our Online Guide PA Sp...

Страница 17: ...operating elements 1 POWER Mains switch Turns the device on and off 2 LED panel SIG Indicates the presence of an input signal Front panel Connections and operating elements E 400 E 800 E 1200 E 1500 1...

Страница 18: ...ature of the amplifier blocks has reached 85 C n One or more protection circuits have been triggered or the device is faulty POWER Lights up green when the device is turned on In standby mode the LED...

Страница 19: ...off switch for standby function If the standby function is enabled the device automati cally switches to standby mode after fifteen minutes without any input signal Rear panel E 400 Connections and o...

Страница 20: ...he earth pin of the device and the signal ground of the device 10 LIMITER Limits the output level so that the maximum distortion is 5 11 Selector switch for operating mode n PAR Parallel mode n STE St...

Страница 21: ...Power cord 16 ON OFF STANDBY On off switch for standby function If the standby function is enabled the device automati cally switches to standby mode after fifteen minutes without any input signal Re...

Страница 22: ...22 INPUT Input channel B A n XLR chassis socket n inch 6 35 mm jack balanced or unbalanced 21 GROUND LIFT Ground lift switch If hum is caused by a ground loop you can use this switch to disconnect th...

Страница 23: ...8 29 OUTPUT Output channel B A n Speaker Twist chassis connector for speaker output 1 2 positive 1 2 negative n Screw terminals Rear panel E 1200 E 1500 Connections and operating elements E 400 E 800...

Страница 24: ...n XLR chassis socket male n XLR chassis socket female 31 Selector switch for operating mode n PAR Parallel mode n STR Stereo mode n BRI Bridged mode Connections and operating elements 24 E 400 E 800...

Страница 25: ...k balanced 20 k balanced 10 k unbalanced 10 k unbalanced Output connections 2 Speaker Twist panel connector 2 Speaker Twist panel connector 4 terminal clamp 4 terminal clamp Output power 8 stereo 2 12...

Страница 26: ...0 Sensitivity 0 775 V 26 dB 1 4 V 0 775 V 26 dB 1 4 V Gain 34 dB 0 77 V 28 dB 1 4 V 36 dB 0 77 V 31 dB 1 4 V Attack time 20 ms 20 ms Power consumption Typical current draw depending on the output powe...

Страница 27: ...0 A 250 V slow blow DC 5 mm 20 mm 15 A 250 V slow blow AC RFMB 103 11D3N B A 88 Series 10 A 250 V Dimensions W H D 482 mm 88 mm 317 mm 482 mm 88 mm 375 mm Weight 8 6 kg 12 8 kg Ambient conditions Temp...

Страница 28: ...el connector 2 Speaker Twist panel connector 4 terminal clamp 4 terminal clamp Output power 8 stereo 2 800 W RMS 8 stereo 2 950 W RMS 4 stereo 2 1200 W RMS 4 stereo 2 1430 W RMS 8 bridged stereo 1 240...

Страница 29: ...tput power level RMS value ARMS All values based on a 230 V mains voltage and a 1 kHz input signal at 0 dB sine 2 880 W 4 2 1050 W 4 2 540 W 8 2 640 W 8 Inrush current 12 A 4 ms 12 A 4 ms Supply volta...

Страница 30: ...15 3 kg 16 0 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 20 80 non condensing 2 stable No DSP crossover No Convection cooling No Further information Technical specifications 30...

Страница 31: ...d shielding while the signal is trans mitted through the core Unbalanced transmission is susceptible to electromagnetic interference especially at low levels such as microphone signals and when using...

Страница 32: ...Signal out of phase 3 Ground 1 Signal left 2 Signal right 3 Ground 1 4 TS phone plug mono unbalanced 1 4 TRS phone plug mono bal anced 1 4 TRS phone plug stereo unbalanced Plug and connection assignme...

Страница 33: ...in phase 3 Signal out of phase 4 Shielding on plug housing option 1 Ground shielding 2 Signal 3 Bridged to pin 1 XLR plug balanced XLR plug unbalanced Plug and connection assignment E 400 E 800 E 120...

Страница 34: ...al 2 in phase 2 Signal 2 out of phase Drawing and table indicate the pin assignment of an RCA plug 1 Signal 2 Ground shielding Speaker Twist chassis connector RCA connection Plug and connection assign...

Страница 35: ...on a reg ular basis Before cleaning switch off the device and disconnect mains operated devices from the mains Only use pH neutral solvent free and non abrasive cleaning agents Clean the unit with a s...

Страница 36: ...rkings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste...

Страница 37: ...Notes E 400 E 800 E 1200 E 1500 37 Power Amplifier...

Страница 38: ...Notes 38 E 400 E 800 E 1200 E 1500 Power Amplifier...

Страница 39: ......

Страница 40: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: