SZComark Cj-KFx1 Скачать руководство пользователя страница 3

   

Shenzhen Comark Technology Co., Ltd   

              More Reliable Connection, More Intellegent Life

 

Tel:86-0755-26055466/26055499                            - 3 -                               web:www.comark.cn/en 

PWR 

Power indicator 

Power on when work normally.   

ANA 

Analog channels 

(current, voltage) state 

indicator 

1. Off--no analog signal (I/V) input or output. 

2. Blinks--when there are input/output channels and its values are in the 

normal range between (4-20 mA / 0 – 5V/ 0-10V). 

3. On--when there are input/output channels and its values are over the 

normal range.   

OPT 

No optical and data 

receiving indicator 

1. On—optical module no receiving channel or abnormal. 
2. 

Blinks—optical module receiving channel normal and has data
receiving. 

3. Off—optical module receiving channel normal, but no data receiving. 

DIGI 

Digital channel 

receiving indicator 

(dry contact or TTL 

signal) 

1. Off—the device has no digital signal input function.   
2. On—the device has digital signal input function. 

COM1-2 

Serial port state 

indicator 

1. Off—no data receiving on corresponding serial port.   
2. On—receiving date on corresponding serial port. 

Analog/digital/serial 

This series product can choose 1 ~ 4 chs analog signal, 1 ~ 4 chs digital signal, 1 ~ 2 chs serial signals independently using or 

division multiplexing, which realize one-way or two-way optical fiber transmission. To describe the direction of signal transfer for 

convenience, it makes artificial distinction between optical transmitter and optical receiver. The equipment should match with 

each other and every port must connect with the right one correspondingly when using. The factory should arrange the 

production according to the goods requirement and the right channel order named 1, 2, 3, and 4.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog signal (Voltage or current) interface 

Содержание Cj-KFx1

Страница 1: ...nal Support 1 4 channel voltage current analog signal Reference accuracy 0 5 25 C Update rates 1000 2000 Hz Signal resolution 10bit Time delay 10ms Voltage signal interface parameters Voltage transmis...

Страница 2: ...99 2 web www comark cn en Installation 35mmDIN Rail Wall Mounting Weight 800g Environmental Operating Temperature 40 to 7 5 Storage Temperature 40 to 8 5 Ambient Relative Humidity 90 non condensing Wa...

Страница 3: ...iving indicator dry contact or TTL signal 1 Off the device has no digital signal input function 2 On the device has digital signal input function COM1 2 Serial port state indicator 1 Off no data recei...

Страница 4: ...r wire input method when connecting to PLC 0 5 VDC and 0 10 VDC output Ai is the reference earth wire for each output signal while Ai is the positive signal wire for each output signal Note output cur...

Страница 5: ...RX2 Dual RS485 model A2 SHIELD shield ground B2 A1 SHIELD shield ground B1 RS232 RS485model TX1 GND data ground RX1 A1 SHIELD shield ground B1 RS422 model TX SHIELD shield ground TX RX SHIELD shield...

Страница 6: ...box Packing list is as follows Multi channel fiber optic converter with industrial terminal block for power equipment Product specification Product warranty card Cautions The Voltage of power supply s...

Страница 7: ...0VDC SM fiber 0 20Km ST SC FC optional Cj VFx2 1 4 channel bidirectional analog signal fiber optic converters 0 10VDC SM fiber 0 20Km ST SC FC optional Cj SFx1 1 2 chs serial signal fiber optic conver...