SYStronics AC-3301L Скачать руководство пользователя страница 9

AC-3301L MANUAL

9

Product Installation Method

3. Align the guide provided with the product with the groove on the back side of the controller, and fix the

controller securely so that it does not move, using the guide fixing screws (2EA / N3).

4. Connect the terminal block to the left side of the controller and proceed with wiring.

Содержание AC-3301L

Страница 1: ...ER MANUAL Integrated Air Conditioner Controller VER 201806 1 0 SYStronics Co ltd 1404 301 Bucheon Techno park 345 Seokcheon ro Bucheon si Gyeonggi do Republic of Korea Phone 10 32 324 2777 Fax 10 32 3...

Страница 2: ...unlight 4 Places affected by electromagnetic waves 5 Places where high temperature or humidity is high sites with over 85 of ambient humidity 6 Places where dust and salt are plentiful Precautions on...

Страница 3: ...It can be linked with remote management system using RS 485 communication It is able to express the operation and alarm status of controller through LCD liquid crystal display And the display and I O...

Страница 4: ...NTC Sensor 1EA SCTS 01 Basic Type Standard Sensor Advanced Type NTC Sensor 1EA SCTS 02 Selectable Option Sensor Well Type NTC Sensor 1EA SCTS 04 Selectable Option Sensor Choose one of the three sensor...

Страница 5: ...condensing Operation humi 5 90 Non condensing Storage temp 20 60 Non condensing Body weight 358g Guide weight 63g Normal Type Cable Sensor SCTS 01 Basic type standard sensor Temperature Range 45 80 Ac...

Страница 6: ...AC 3301L MANUAL 6 Product Dimension Top view Front view Guide Dimension Unit mm Controller Dimension Unit mm Side view Top view Front view Side view...

Страница 7: ...e Basic 3M standard Advanced Type Cable Sensor SCTS 02 Selectable type option sensor Temperature Range 45 105 Accuracy NTC 10K at 25 0 5 Sensor Weight 37 5g Cable Basic 3M standard Normal Type Cable S...

Страница 8: ...thod 1 Remove the two terminal blocks located on the left side of the controller for mounting on perforated panels or equipment 2 Punched holes W111 0 x H126 0 mm to fit the panel or equipment and the...

Страница 9: ...de provided with the product with the groove on the back side of the controller and fix the controller securely so that it does not move using the guide fixing screws 2EA N3 4 Connect the terminal blo...

Страница 10: ...eck the polarity of the wiring before connecting the wiring correctly 2 To avoid malfunction due to noise from the product avoid the use of the same conduit or the same duct for the wiring of high vol...

Страница 11: ...o parameter setting Press for 5 seconds Return to main screen Press short Save button Save changed setting value Press short Up button Go to top menu Press short long Down button Go to bottom menu Pre...

Страница 12: ...1 EQUIP NO 1 2 POWER REC 10s 3 STOP DELAY 90s Integration Time COMP1 0 COMP2 0 HEATER1 0 Alarm Status 1 FAN ALARM 2 TEMP SENSOR Backlight Setting Backlight ON 1 S TEMP 24 0 2 COOLING DIFF 1 0 Operatio...

Страница 13: ...us such as blowing cooling and heating operation Alarm Status Screen Up to 8 alarms are displayed and the most recent alarms are displayed at the top If the number exceeds 8 the oldest alarm is automa...

Страница 14: ...mperature of the air conditioner Cooling Diff 0 1 5 0 1 0 Set the operation and stop deviation of cooling operation by the cooling deviation temperature for set temperature Current temperature Setting...

Страница 15: ...function sets the heating step Temp Cali 10 10 0 0 The temperature value is corrected when the actual temperature differs from the actual temperature value inside the room If the room temperature is...

Страница 16: ...Fan Alarm It occurs when the contact point does not come in for 5 seconds after blower output Check blower contacts Check the equipment status of the blower H Temp Alarm Occurs when the current tempe...

Страница 17: ...the precautions and instructions specified in the manual For more information on the service refer to the product warranty statement in the user manual 1 Please note that any problem failure caused by...

Страница 18: ...to generate noise 4 Noise source may occur due to contact switching Among the causes of the above noise sources the noise that the system manufacturer can reduce is only the contact switching noise Co...

Страница 19: ...e to install close to the line where the noise is generated and the line where the noise is generated by placing a plated steel barrier 2 If you need a lot of noisy power in area A it is recommended t...

Страница 20: ...oil s positive or negative terminal or an equivalent snubber capacitor Generally 100 and 0 1Uf are connected in series but it needs to be adjusted according to the load power How to Identify the Sourc...

Страница 21: ...AC 3301L MANUAL 21...

Отзывы: