EMI TYPE TESTS

TEST

            DESCRIPTION

TEST LEVELS

IEC 61000-4-2

ESD

Enclosure Contact

+/-  8KV

Enclosure Air

+/-  15KV

IEC 61000-4-3

Radiated 

RFI

Enclosure ports

20 V/m

IEC 61000-4-4

Burst (Fast 

Transient) 

Signal ports

+/-  4KV @ 5KHz, 1 min

D.C. Power ports

+/-  4KV @ 5KHz, 1 min

Earth ground ports

+/-  4KV @ 5KHz, 1 min

IEC 61000-4-5

Surge

Signal ports

+/-  1KV line-to-line

D.C. Power ports

+/-  2KV line-to-earth

+/-  1KV line-to-line

IEC 61000-4-6

Induced

(Conducted

RFI)

Signal Ports 10V

10V

D.C. Power ports

10V

Earth ground ports

10V

IEC 61000-4-8

Magnetic

Field

Enclosure ports

100 A/m continuous, 1000 A/m for 1s

IEC 61000-4-29

Voltage Dips

& Interrupts

D.C. Power ports

18 VDC-30%

18 VDC-60%

18 VDC-100%

18 VDC+/-20%

60 VDC-30%

60 VDC-60%

60 VDC-100%

60 VDC+/-20%

IEC 61000-4-16

Main

Frequency

Voltage

Enclosure ports

20 V/m

IEC 61000-4-17

Ripple on

D.C. Power

Supply

D.C. Power ports

15% of rated voltage

IEC 60255-5

Dieletric

Strength

Signal ports

705 VDC, 1 min (Ethernet)

705 VDC, 1 min (Relay)

705 VDC, 1 min (Relay Contacts)

D.C. Power ports

705 VDC

IEC 60255-5

H.V. Impulse

D.C. Power ports

5KV

Содержание DVS500

Страница 1: ...hIntelligence com 2018 Systems With Intelligence All rights reserved DVS500 INSTALLATION GUIDE Version 1 0 SUBSTATION HARDENED DIGITAL VIDEO SERVER Note Please read this manual thoroughly before opera...

Страница 2: ...of Systems With Intelligence Inc Disclaimer of Liability We have checked the contents of this manual against the hardware and software described However deviations from the description cannot be comp...

Страница 3: ...he interference on his own expense CAUTION This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT CAUTION Use of controls or adjustments or performance of procedures other t...

Страница 4: ...m 5 1 2 Technical Specifications Overview 6 2 Dimensions 7 3 Power Supply 8 3 1 Power Supply Wiring 9 3 2 Dual Redundant Power Supply 9 4 Failsafe Relay 10 5 IP Camera Input 11 6 Serial Interface 12 6...

Страница 5: ...x USB 2 0 Ports Digital Inputs 4 x Digital Inputs Digital Outputs 4 x Digital Outputs Mounting DIN rail mounts Substation Hardened IEC 61850 3 IEEE 1613 C37 90 400 C to 750 C Future option available s...

Страница 6: ...es supported ONVIF IP Camera Support CPU Atom E3845 1 91GHz RAM 4GB DDR3L Power 30W Max Video Output 1 HDMI interface for computer monitor USB 2 USB 2 0 Ports Storage Up to 1TB LAN Interface Included...

Страница 7: ...ystemsWithIntelligence com support SystemsWithIntelligence com 2017 Systems With Intelligence All rights reserved 7 INSTALLATION 2 Dimensions Note Units in Imperial Metric 3 72 in 94 5 mm 6 34 in 161...

Страница 8: ...SUPPLY TYPE INPUT RANGE INTERNAL FUSE RATING POWER CONSUMPTION MIN MAX TYPICAL WORST CASE 24 48 VDC 20 VDC 60 VDC 5A T 15 W 20 W 25 W 30 W TERMINAL NUMBER DESCRIPTION USAGE Screw Chassis Ground Chassi...

Страница 9: ...otes Equipment must be installed according to the applicable country wiring codes Connect the ground terminal on the power source to the chassis ground terminal on the DVS500 3 2 Dual Redundant Power...

Страница 10: ...tput contact that can be used to communicate an alarm to another system e g remote terminal unit if the server stops working The failsafe relay is in open state normally open when the server is powere...

Страница 11: ...IP Camera Input The DVS500 can be equipped with IP video inputs 4 port IP Camera Input cards are available with fiber optic SFP based LC connectors or RJ45 connectors All ports support 100Mbps inputs...

Страница 12: ...4 relay switch output 30 VDC 1 Amp 50 VAC 5 Amps 6 1 Dry Contact Input Interface Connector Connector Part Number 1727570000 Manufacturer Weidm ller Description Conn Term Block 3 5mm pitch 8POS SN OR...

Страница 13: ...Y1 O Common relay output 3 NO_RELAY2 O Normally open relay output 4 COM_RELAY2 O Common relay output 5 NO_RELAY3 O Normally open relay output 6 COM_RELAY3 O Common relay output 7 NO_RELAY4 O Normally...

Страница 14: ...568 A wiring standard that characterizes minimum cabling performance specifications required for proper Gigabit Ethernet operation To ensure reliable error free data communications new and pre existi...

Страница 15: ...the DVS500 has been designed to meet 8 1 Temperature Humidity 8 2 EMC EMI ESD 1 IEC 61850 3 Electric Utility Substations 2 IEEE 1613 Electric Utility Substations 3 IEC 61000 6 2 Industrial Generic 4...

Страница 16: ...ne D C Power ports 2KV line to earth 1KV line to line IEC 61000 4 6 Induced Conducted RFI Signal Ports 10V 10V D C Power ports 10V Earth ground ports 10V IEC 61000 4 8 Magnetic Field Enclosure ports 1...

Страница 17: ...x EMI IMMUNITYPE TESTS TEST DESCRIPTION TEST LEVELS IEEE C37 90 3 ESD Enclosure Contact 2KV 4KV 8KV Enclosure Air 4KV 8KV 15KV IEEE C37 90 2 Radiated RFI Enclosure ports 20 V m IEEE C37 90 1 Fast Tra...

Страница 18: ...ries info SystemsWithIntelligence com Sales Inquiries sales SystemsWithIntelligence com Product Support support SystemsWithIntelligence com All specifications in this document are subject to change wi...

Отзывы: