INSTALLATION
All Systembase C600ip series codecs are designed
to fit a standard 19” rack. Each unit measures
44.45mm high (1U). Notes for installing:-
1/ Do not obstruct any air vents that the product may
have.
2/ Do not mount the unit directly above or below
other equipment within the rack. It is recommended
to leave a space of 1U between units.
3/ Where possible connect the M4 earth bonding
point to the rack enclosure frame.
FRONT PANEL LAYOUT
Reset Button
Located on the front panel is a recessed factory
RESET button. To initiate a factory reset please
ensure that the unit is powered on and depress the
button. The Front panel LEDS will flash and the unit
will reset to factory default.
System Status LED
This blue LED has two functions. An illuminated
Stead state it indicates that the unit has power and
that the management port LAN connection is active.
If the LED is flashing then this means that the
management port LAN connection is not active.
Codec Status LED
This blue LED has two functions. When illuminated
Stead state it indicates that the unit is in SYNC and
has an active AoIP/SIP connection.
If the LED is flashing then this means that the AoIP
Ethernet port does not active .
Page 4