background image

7

Operation

Caution

EC motors must be set to ON/OFF via
the control input. To stop the product via
mains supply decreases the life time of
the motor. Systemair recommends to
install external speed controller for easy
access to control the input signal.

7.1

To start a product with an EC
motor

1

Make sure that the 0–10 V signal is set to “0” with the
speed controller.

2

Set the installed safety switch in the ON position and wait
5 seconds.

3

Adjust the fan speed with the 0–10 V signal speed con-
troller. If an external speed controller is not installed, ad-
just the fan speed directly with the integrated
potentiometer.

7.2

To stop the product

1

Set the installed speed controller in the OFF position.
Refer to the instruction manual for the installed speed
controller.

2

Set the installed safety switch in the OFF position.

7.2.1

To stop the product in an
emergency

• Set the installed safety switch in the OFF position.

8

Maintenance

Warning

Set the installed safety switch in the OFF position before you do the maintenance unless the instructions tell
you differently. Make sure that the safety switch is not accidentally set in the ON position.

8.1

Maintenance schedule

The intervals are calculated from continuous operation of the product.

Maintenance task

Usual operation

conditions

Unusual operation conditions.

1

Each 6

months

Each

year

Each 3

months

Each 6

months

Each

year

Visually examine the product and its components for damage,
corrosion and dirt.

X

X

Examine the fan impeller for damage and imbalance.

X

X

Clean the product and the ventilation system.

X

X

Do a check of all fasteners and make sure that they are fully
tightened.

X

X

10

Содержание TFC-P Roof fan EC

Страница 1: ...Installation Operation and Maintenance instruction EN TFC P Roof fan EC TFC S Roof fan EC...

Страница 2: ...5 3 Speed controller for EC motors 9 5 4 Motor protection for EC motors 9 6 Commissioning 9 6 1 To do before the commissioning 9 6 2 To do the commissioning 9 7 Operation 10 7 1 To start a product wit...

Страница 3: ...uct is used for transportation of clean or contami nated air with a maximum temperature of 60 C in continuous operation The product is intended for installation outdoors on commer cial and residential...

Страница 4: ...e The data on the name plate applies to standard air that is specified in the standard ISO5801 1 5 1 Type designation Product name TFC P TFC S Dimension 225 225 280 280 355 355 450 450 500 500 560 560...

Страница 5: ...adjacent area during all work on the product Make sure that you know how to stop the product quickly in an emergency Use applicable safety devices and personal protective equipment during all work on...

Страница 6: ...If you install the product with free suction or free dis charge it is necessary to install a protection grille Make sure that the safety distance agrees with the standard DIN EN ISO 13857 and the stan...

Страница 7: ...Release the lock by pulling the lever beside the lock Caution Keep fingers away from the back of the hinge The back of the hinge is a poten tial pinch point Note TFC 225 and TFC 280 have no handle Ho...

Страница 8: ...the roof in accordance with applicable building standards and connect the fan to a duct system Note Obey local laws and regulations for installation of the roof curb on the roof 7 Close the electrica...

Страница 9: ...the pressure setpoint Setpoint 1 The normal operation pressure setpoint Setpoint 2 The pressure setpoint during a secon dary operation mode 10 Press Down to go to T Band SA and set the tempera ture r...

Страница 10: ...nd press P to select the desired measuring range 1 0 1000 Pa 2 0 500 Pa 3 0 300 Pa 4 0 200 Pa 6 Press Down to go to K Factor and set the K factor de pending on your product size Refer to the table 1 K...

Страница 11: ...until the vibrations are decreased Continuous strong vibrations can cause damage to components Do not increase the fan speed to a higher rpm value than the maximum value that is given on the name pla...

Страница 12: ...ion manual for the installed speed controller 2 Set the installed safety switch in the OFF position 7 2 1 To stop the product in an emergency Set the installed safety switch in the OFF position 8 Main...

Страница 13: ...ons are classified as follows If a stable ambient temperature is higher than 30 C or lower than 10 C if the temperature changes are large or if very contaminated air is transported 8 2 To clean the pr...

Страница 14: ...e 9 The air output is not sufficient The fan impeller does not turn in the correct direction Make sure that the electrical connection is correctly done The electrical connection is not correctly done...

Страница 15: ...al blockage Remove the blockage Phase loss occurs If the motor is a 3 phase motor make sure that no phase is missing The motor does not rotate A component in the power supply is defective Do a check o...

Страница 16: ...ed at an approved disposal location for electrical and electronic equipment 10 1 To disassemble and discard the parts of the product 1 Disconnect and disassemble the product in the opposite sequence o...

Страница 17: ...re of transported air C 60 Sound pressure dB Refer to the data sheet in the online catalogue at www systemair com Corrosion class IP class Voltage current frequency enclosure class weight Refer to the...

Страница 18: ...Abbreviation in wiring diagram Cable colour RD Red YE Yellow BU Blue WH White GN Green BN Brown BK Black GR Grey GY Green Yellow 12 3 1 Wiring diagrams for TFC P fans TFC P fans 1 phase 230 V TFC P 2...

Страница 19: ...TF Us 13 14 2 ID1 ID2 GND GND A A B B 10 24VDC WH BU YE RD GND Us BK WH BN GN YE BN BU T24 24V 230V 2 1 4 3 PE L1 N PE L1 L1 L1 L2 L3 N NC COM N L2 PE BU BN GN YE N NC C 3 8 4 5 6 7 2 9 1 11 12 10 15...

Страница 20: ...16 TFC P 560 1 Safety switch 2 Aux contact Signal relay 3 24 V DC 4 0 10 V out 5 0 10 V out 6 Digital input 7 Digital input 8 Temperature 9 Modbus slave 10 Transformer 11 Connection box 12 Pressure co...

Страница 21: ...ection box 2 0 10 V DC Ext 3 Time 1 min 4 Safety switch 5 Motor 6 230 V 1 TFC S fans 1 phase 230 V TFC S 355 4 BK BU GN YE GN YE BU BN WH 1 WH 2 5 2 1 4 3 PE L N RSA RSB BN BU WH YE RD DC GN YE BN BU...

Страница 22: ...RD M L2 L1 GN YE L3 WH WH PE L1 L2 L3 NC COM GN YE BN BK GY PE L1 L2 L3 4 5 TFC S 560 1 Connection box 2 0 10 V DC Ext 3 Time 1 min 4 Alarm 5 Safety switch 6 ON OFF 7 Motor 8 230 V 1 12 3 3 Pressure...

Страница 23: ...as with higher pressure 7 Digital input D1 terminals 1 2 8 Input outdoor temperature sensor terminals TF TF 9 MODBUS interface terminals GND A B ID1 ID2 and jumper J1 12 3 4 Wiring diagrams for speed...

Страница 24: ...MTV 1 10 MTV 1 010 1 IN Vac 2 IN Vac 4 Out 5 Out 10V 0 10V GND 230V AC S 5EC FRQ MTP 10 GND 10V A 10V 0 10V GND EC Vent EC Vent IN RPM PWM IN 10V OUT PWN GND TACH optional 10V 0 10V PWM GND 22...

Страница 25: ...y NO Relay NC 10V 0 10V GND Din1 12 3 6 Wiring diagrams for demand control for EC motors EC Basic EC Basic T for temperature control EC Basic 230V AC 1 IN Vac 2 IN Vac 4 Out 5 GND 10V 0 10V GND EC Bas...

Страница 26: ...stem has 2 units The control board CB and the room unit RU Connect the fan to the control board and remove the internal potentiometer EC Vent IN RPM PWM IN 10V OUT PWN GND TACH optional 10V 0 10V PWM...

Страница 27: ...GND A D PT1000 24V N out N in L out L in IN3 IN2 IN2 A Mains supply 230 V 1 AC 10 A B Analogue sensor for example pressure sensor C Analogue sensor for example pressure sensor type PT1000 D Digital s...

Страница 28: ...Output minimum 0 10V Output maximum 0 10V PCA 1000D2 Pressure controller For constant air volume control CAV or variable air volume control VAV GND A GND 1 2 US US PCA 1000 6000D2 10 24 V DC p p V PI...

Страница 29: ...2 1 1 TFC P TFC S fan 2 Roof curb TG Note For more information about accessories refer to www systemair com or speak to Systemair technical support 27...

Страница 30: ...s IP Code Directive electromagnetic compatibility EMC 2014 30 EU EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposur...

Страница 31: ...lations 2016 EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure EN 61000 6 2 2005 Electromagnetic compatibility EM...

Страница 32: ...r AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair Sverige AB In...

Отзывы: