SystemAir KBR Скачать руководство пользователя страница 4

1.5

Name plate

1

7

8

9

11

12

2

3

4

5

6

13

10

1.

Type designation: Product name, dimension and motor
type. Refer to

1.5.1 Type designation page 2

.

2.

Current, A

3.

Input power, W

4.

Frequency, Hz

5.

Certifications

6.

Scannable code

1

7.

Voltage, V

8.

IP class, enclosure class

9.

Insulation class

10. Serial number: part number/production number/produc-

tion date

11. Nominal fan speed

12. Weight, kg

13. Country of production

Note:

The data on the name plate applies to “standard air” that is
specified in the standard ISO5801.

1.5.1

Type designation

Product name

KBR

KBR EC

KBR/F

Dimension

280

280

280

315

315

315

355

355

355

Motor type

D2: 2 pole, 3–phase

EC: Electronically commuted
1–phase

D2: 2 pole, 3–phase

D2–4: 2–4 pole, 3–phase

EC-K: Electronically com-
muted 1–phase, normal
power

D2–4: 2–4 pole, 3–phase

DV: 4 pole, 3–phase

EC-L: Electronically com-
muted 1–phase, high power

DV: 4 pole, 3–phase

E4: 4 pole, 1–phase

E4: 4 pole, 1–phase

1.6

Product liability

Systemair is not liable for damages that the product causes
in these conditions:

• The product is incorrectly installed, operated or

maintained.

• The product is repaired with parts that are not original

spare parts from Systemair.

• The product is used together with accessories that are not

original accessories from Systemair.

• The product is used without motor protection.

2

Safety

2.1

Safety definitions

Warnings, cautions and notes are used to point out specially
important parts of the manual.

Warning

If you do not obey these instructions,
there is a risk of death or injury.

Caution

If you do not obey these instructions,
there is a risk of damage to the product,
other materials or the adjacent area.

2

1.

Use a mobile device to scan the scannable code and go to the Systemair documentation portal for more documentation and document

translations.

Содержание KBR

Страница 1: ...Installation Operation and Maintenance instruction KBR Thermo box fan AC KBR Thermo box fan EC KBR F Smoke extraction fan...

Страница 2: ...5 5 Speed controller for AC motors 5 5 6 To install motor protection for AC motors 6 6 Commissioning 6 6 1 To do before the commissioning 6 6 2 To do the commissioning 6 7 Operation 7 7 1 To start a p...

Страница 3: ...mperature of 400 C for 2 hours one time If KBR F has a maximum constant airflow temperature of 400 C for 2 hours it must be replaced The product is not applicable for transportation of air that contai...

Страница 4: ...4 pole 3 phase EC L Electronically com muted 1 phase high power DV 4 pole 3 phase E4 4 pole 1 phase E4 4 pole 1 phase 1 6 Product liability Systemair is not liable for damages that the product causes...

Страница 5: ...occur depending on model and size Visit www systemair com for more de tailed information about your product The product is not to be used by persons including chil dren with reduced physical sensory o...

Страница 6: ...at the installation location Make sure that the information on the name plate and the motor name plate agrees with the operation conditions Install the product in a location where there is space for...

Страница 7: ...he con nection box 5 2 To connect the product to the power supply Complete the electrical connection for the motor Refer to the motor wiring diagram that is included with the product Make sure that th...

Страница 8: ...sure that the safety devices are correctly installed Make sure that there are no blockages in the air inlet and the air outlet Make sure that installation material and unwanted objects are removed fro...

Страница 9: ...To start a product with an AC motor 1 Set the installed safety switch in the ON position 2 Install the external speed controller Refer to the instruc tion manual for the installed speed controller 7...

Страница 10: ...cable connections for damage Make sure that the cable glands are tight against the cables X X If flexible connections are installed examine them for damage X X 1 The unusual operation conditions are...

Страница 11: ...il the product operates smoothly Refer to 6 Commissioning page 6 The air output is not sufficient The fan impeller does not turn in the correct direction Make sure that the electrical connection is co...

Страница 12: ...al blockage Remove the blockage Phase loss occurs If the motor is a 3 phase motor make sure that no phase is missing The motor does not rotate A component in the power supply is defective Do a check o...

Страница 13: ...ed at an approved disposal location for electrical and electronic equipment 10 1 To disassemble and discard the parts of the product 1 Disconnect and disassemble the product in the opposite sequence o...

Страница 14: ...roduct that is not operated continuously is operated for a minimum of 1 hour each month 12 Technical data 12 1 Technical data overview KBR KBR F Maximum temperature of transported air C 120 200 Sound...

Страница 15: ...34 55 KBR 280 EC 171 125 537 295 360 625 29 291 115 280 50 50 620 38 234 55 KBR 315 AC 187 5 125 600 339 398 690 29 307 115 315 50 50 770 38 249 55 KBR F 315 AC 187 5 60 600 339 398 690 29 307 50 315...

Страница 16: ...12 3 1 Wiring diagrams for speed controllers for EC motors Note An internal potentiometer is installed on the terminal block from the factory Remove the internal potentiometer when you use an external...

Страница 17: ...MTV 1 10 MTV 1 010 1 IN Vac 2 IN Vac 4 Out 5 Out 10V 0 10V GND 230V AC S 5EC FRQ MTP 10 GND 10V A 10V 0 10V GND EC Vent EC Vent IN RPM PWM IN 10V OUT PWN GND TACH optional 10V 0 10V PWM GND 15...

Страница 18: ...diagrams for ON OFF controls for EC motors CO2RT R D CO2RT R D 24V AC Supply Neutral Common Relay NO Relay NC 10V 0 10V GND Din1 IR24 P IR24 P 24V AC or DC 24V Neutral Common Relay NO Relay NC 10V 0 1...

Страница 19: ...or KBR F fans 3 LRK Airflow shutter 4 UGF Transition flange 5 ASF Flexible connection applicable for KBR fans 6 WBK Wall bracket 7 ALS Drain plug 8 WSD Motor weather protection Note For more informati...

Страница 20: ...agnetic compatibility EMC Part 6 1 Generic standards Immunity for residential commercial and light industrial environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Part 6 4 Gener...

Страница 21: ...c Compatibility Regulations 2016 2014 30 EU DIN EN IEC 61000 6 1 2019 11 Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residential commercial and light industrial environme...

Страница 22: ...rves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair GmbH Seeh fer Str 45 9...

Отзывы: