DIMENSIONS
A
B
C
D
Model/Modèle
A
B
C
D
Rn2X
5 7/8 (149)
11 1/2 (292)
1 1/4 (32)
9 1/4 (235)
Dimensions in inches (mm).
Dimensions en pouces (mm)
INSTALLATION
The Rn2X is designed for use with 3" and 4" schedule 40 PVC pipe, when
appropriate LDVI
™
coupling is used.
Prior to installation, the suction pipe should be terminated at the exterior
wall. The suction pipe should be installed with slight incline to drain water
from the fan.
DO NOT connect fan directly to building structure
Motor
Leads
Supply
Voltage
Brown
Black
Capacitor
L (Black)
N (White)
Blue
WIRING DIAGRAM
There are typically three wires to be connected to an electrical fan;
Load, Neutral and Ground. Load provides power to the fan, Neutral is
for returning current and closing the electrical circuit, and Ground is
for an additional path to safely return current to the ground, in case of
an accidental electrical short in the fan and/or discharging of fan metal
components.
Fantech radon fans are permanently connected appliances employing
a reinforced polymeric construction.
The non-conductive construction
functions as a “Double Insulated” protective System (Complies with
Standard for Double Insulation Systems for Use in Electrical Equipment, UL
1097), thus eliminating the need for a grounding conductor.
All Fantech
radon fans are tested and reviewed by Underwriter Laboratories, a 3rd
party independent safety governing body, and deemed suitable for outdoor
use (Standard for Safety-Electric Fans, UL 507).
Please contact Fantech Technical Support if additional information is
needed regarding this matter.
Radon fans are to be installed in the vertical orientation ONLY.