background image

Roof

fan

plastic

·Installation

and

Operating

Instructions

··

en_GB

·2019-10-14

·002

Systemair GmbH
Seehöfer Str. 45
97944 Boxberg
Germany

Tel.: +49 (0)7930/9272-0
Fax: +49 (0)7930/9273-92

[email protected]
www.systemair.de

Содержание DVP 200DD2-4

Страница 1: ...Document in original language 002 Roof fan plastic DVP Installation and Operating Instructions GB...

Страница 2: ...emair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agr...

Страница 3: ...al components 5 5 4 Intended use 5 5 5 Incorrect use 5 6 Name plate and type key 6 7 Accessories 7 8 Installation 7 8 1 Installation positions 8 9 Electrical connection 8 9 1 Protecting the motor 9 9...

Страница 4: ......

Страница 5: ...the fan They must always be available at the place of use Observe and respect local conditions regulations and laws Abide by the system related conditions and requirements of the system manufacturer...

Страница 6: ...e electrical system from live components at all terminals 2 Prevent reactivation 3 Test absence of voltage 4 Ground and short circuit 5 Cover or restrict adjacent live parts 3 Warranty For the asserti...

Страница 7: ...e motor or other sensitive parts We recommend transporting the fan to the installation site in the original packaging Caution If transported without care during loading and unloading the fan may be da...

Страница 8: ...Drain in vertical position 5 1 Dimension Table 2 Dimensions mm A B C D E F G H K L M DVP 200DD2 4 435 330 200 355 662 200 119 1065 146 30 4x10 DVP 250DD2 4 595 450 250 400 768 250 119 981 181 30 4x12...

Страница 9: ...ents without guarantee for correctness Examination of the media to be transported is a matter for the plant operator Here it is merely a question of a recommendation 5 4 Intended use The fans have bee...

Страница 10: ...h tr min rpm made in France UE IP55 Impeller Poids total Total weight 71 Kgs 560 mm 1 2 3 4 5 6 7 8 9 10 11 12 13 2 Production number 3 Execution 4 Impeller speed 5 Air volume 6 Pressure 7 Input powe...

Страница 11: ...ge 7 8 Installation Safety information Fans installed in areas where personnel access regularly must be equipped with a splinter guard please contact Systemair Observe 2 Important safety information p...

Страница 12: ...on Observe 2 Important safety information page 1 Prevent the ingress of water into the connection box Warning Danger due to electrostatic influence on medical implants e g cardiac pacemaker Persons wi...

Страница 13: ...s so quickly that any vibration cannot exceed the admissible resonant frequency values Observe the operating instructions of the frequency converter Caution Damage as a result of incorrect commissioni...

Страница 14: ...auses Remedy Fan does not run smoothly Impeller imbalance Rebalancing by a specialist company if possible otherwise contact Systemair Soiling on the impeller Clean carefully rebalance Material decompo...

Страница 15: ...ing Contact Systemair Control units if used such as frequency converter or transformer are set incorrectly Correct the settings of the control units Mechanical blockage Remove the blockage Frozen cond...

Страница 16: ...ge 12 X X Check the screwed connections for damages defects and check that they are firmly seated X See normal operating conditions Check the fan intake is free from contamination X X Check that the f...

Страница 17: ...n in reverse order of installation and electrical connection 15 Disposal Ensure material is recycled Observe national regulations The device and the transport packaging are predominantly made from rec...

Страница 18: ...ed cables Motor protection Yes No Motor protection switch or motor protection relay PTC resistor Resistance value Thermal contact Electrical motor protection Others Functional check Yes No Impeller ea...

Страница 19: ...suction side and discharge of the fan If an air flow measurement is not possible this value can be calculated using the following formula X Duct cross section m Flow speed m s Grille measurement acc...