Operation

SAVE CONNECT solution (mobile application and Internet access module) has a similar menu structure and functionality
as SAVE TOUCH control panel, so this section can also be used as a guide for the mobile application.

3.2.1

Common symbols

The following selection symbols are common and are present in most menu pages:

Back button to return to a previous
menu, located at the upper left corner

On and Off slider to activate or
deactivate a function. White bubble —
function is inactive, green bubble —
function is active.

Up arrow to increase a value

CANCEL

Button to cancel changes

Down arrow to decrease a value

SET

/

OK

Buttons to confirm changes

Some menus have more than one page. Touch page indicator in the top right corner to go to the next page. The first
number indicates current page number and the second number indicates a total number of pages available.

Many options show up in a form of the pop-up window. Select the option from the displayed list in the pop-up window
and press

OK

to confirm selection.

3.2.2

Home screen overview

1. Menu

2. Active user mode

3. Temperature settings

4. Airflow settings

5. Alarms and warnings

6. Status line

7. Outdoor temperature

A. Return to home screen

B. Basic read-only information about the unit

C. Currently active alarms and alarm history

D. Configure and check week schedule

E. Check and change remaining time till filter change

F. General system preferences

G. Configuration of all system parameters

H. Help and troubleshooting menu

3.2.3

Status bar and alarms

Status bar indicates all currently active functions. Touch the status bar to see descriptions of active functions in more
detail.

For more information about user modes and functions, please check

Help

menu.

Touch the alarm bar on the home screen to see all active alarms.

254538 | v1

Содержание 488819

Страница 1: ...Document in original language 254538 v1 SAVE VTR 150 B User Manual GB...

Страница 2: ...stemair UAB All rights reserved E OE Systemair UAB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Страница 3: ...nge the temperature 7 3 2 7 To change the airflow 7 3 2 8 To set a week schedule 8 4 Maintenance of the unit 9 4 1 Maintenance Schedule 9 4 2 To access internal components 9 4 3 To change filters 10 4...

Страница 4: ......

Страница 5: ...t Systemair will require these in the case of a warranty claim 1 3 Type label Before calling your service representative make a note of the specification and production number from the type label whic...

Страница 6: ...SAVE LIGHT control panel Fig 2 Explanation of symbols SAVE LIGHT is a basic control panel for SAVE series resi dential air handling units SAVE LIGHT allows to change airflow levels and indicates when...

Страница 7: ...ensation when the unit has been stopped 3 1 3 To cancel sleep mode Press any button to cancel the sleep mode SAVE LIGHT returns to the sleep mode after 3 minutes of inactivity All control panel lights...

Страница 8: ...ge number and the second number indicates a total number of pages available Many options show up in a form of the pop up window Select the option from the displayed list in the pop up window and press...

Страница 9: ...uick information screen shows the following information 1 Time 2 Outdoor temperature 3 Current User mode Alarm 4 Fan speed off Minimum Low Normal High Maximum 5 Supply air temperature 6 Relative humid...

Страница 10: ...irflow setting in Week Schedule Manual Manual selection of airflow levels The unit can be set run at one out of four available airflow speeds Off Low Normal High Note The fan can be set to OFF by acti...

Страница 11: ...ettings of all modes can be modified in Service menu 3 2 6 To change the temperature Touch the thermometer symbol on the home screen to open the temperature settings window Use up and down arrows to i...

Страница 12: ...Use arrow buttons and to increase or decrease value Confirm with OK button Note Scheduled time can start but never end at midnight 00 00 The latest END TIME period is 23 59 Scheduled time cannot go t...

Страница 13: ...ied out correctly and written evidence thereof is provided 4 1 Maintenance Schedule Task 6 months 1 year 3 years When necessary General inspection X Filter change X X Fan cleaning X Heat exchanger cle...

Страница 14: ...set the filter change time Once filter is changed it is necessary to reset filter time Go to Filter menu see 3 2 2 Home screen overview page 4 pos E or if filter alarm is present click on alarm status...

Страница 15: ...not exposed to moisture 4 Remount the rotor Don t forget to reconnect the rotor power and sensor cables 4 5 To clean fans Danger Make sure that the Mains supply to the unit is disconnected before perf...

Страница 16: ...ve the side cover 3 Remove the broken drive belt 4 Use tape to attach the drive belt to the rotating heat exchanger and rotate the exchanger by hand to get hold of the drive belt 5 Remove the tape and...

Страница 17: ...of the installation The duct runs should therefore be cleaned changed when necessary Steel ducts can be cleaned by pulling a brush soaked in hot soapy water through the duct via diffuser louvre openi...

Страница 18: ...panel or via a hardwired switch 6 Check the analogue inputs in the service menu to verify that the temperature sensors are functioning correctly 7 In case of installed electrical other re heater batte...

Страница 19: ...254538 v1...

Страница 20: ...SAVE VTR 150 B User Manual 254538 en_GB 2021 03 15 v1 Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 60166 www systemair com...

Отзывы: