SystemAir 25126 Скачать руководство пользователя страница 1

CO

2

Sensor

Wireless

User Manual

-en_GB

Document in original

language

2017-03-20

A004

Содержание 25126

Страница 1: ...CO2 Sensor Wireless User Manual en_GB Document in original language 2017 03 20 A004...

Страница 2: ...f Conformity 1 2 Product description 2 2 1 CO2 measurement 3 3 Guidelines for installation 3 4 Interface description 4 4 1 Connections 5 4 2 Power up mode 5 4 3 Active User Fault mode 6 4 4 Binding mo...

Страница 3: ...222 440 00 Fax 46 222 440 99 www systemair com hereby confirms that SmartDial CO2 sensor Humidity sensor Input module and RS485 Gateway comply with all applicable requirements in the Directive 2014 5...

Страница 4: ...es the carbon dioxide CO2 level in the air The CO2 level is measured in Parts Per Million PPM If the sensor detects CO2 above a preset level the air handling unit will start forced ventilation The CO2...

Страница 5: ...e unit is powered up Measurement accuracy will be at its maximum 10 minutes after the unit is powered up Note The function of the CO2 sensor is configured in the Systemair air handling unit controller...

Страница 6: ...chine Interface MMI for this product has one capacitive button and one combined red and green LED indicator that indicates the status of the device 1 Green and Red combined LED 2 Capacitive button CO2...

Страница 7: ...230 V AC N 230 V AC 4 2 Power up mode After the device has been turned on the green LED lights up After 2 seconds the device will go to idle mode In the idle mode the status LED s are turned off When...

Страница 8: ...vate the Party Active mode from this module It must be deactivated on the air handling unit control panel or the wireless control panel if one is used Note There is no visible feedback when the button...

Страница 9: ...Note Binding mode must first be activated on the gateway See RS485 Gateway User Manual for more information In the Binding mode the red and green LED s are alternately lit for 2 seconds When the bind...

Страница 10: ...s entered 5 Troubleshooting Indication Probable cause and action CO2 Sensor is not working Check AC power RF binding and or communication problems Check if remote modules too close 1 m or too far away...

Страница 11: ...CO2 Sensor User Manual 9 Systemair AB...

Страница 12: ...reserves the right to make changes and improvements to the contents of this manual without prior notice Systemair AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440...

Отзывы: