[4] Contents Of The Duct Smoke Detector Kit

1.  Complete housing base and cover assembly
2.  Two #10

×

1

1

4

 sheet metal screws for mounting

3.  Two sampling tube filters
4.  One test magnet
5.  Drilling template
6.  Two foam gaskets
7.  Four  #6-self  tapping  mounting  screws  for  the  metal 

sampling tube and optional exhaust tube extension

8.  One inlet tube end plug
9.  One plastic sampling tube
10. One #8 self-tapping screw for the plastic sampling tube

NOTE:

  For ducts over 1

1

2

 feet, longer inlet sampling tubes 

must be ordered to complete the installation. They 
must be the correct length for the width of the duct 
where they will be installed. See Table 1 on page 
3 to determine the inlet tube required for different 
duct widths.

[5] Installation Sequence                                      
[5.1] Verify Duct Air Flow Direction And Velocity

Model DH100ACDCP detectors are designed to be used in 
air  handling  systems  having  air  velocities  of  500  to  4000 
feet per minute. Be sure to check engineering specifications 
to ensure that the air velocity in the duct falls within these 
parameters. If necessary, use a velocity meter to check the 
air velocity in the duct.

[5.2] Drill The Mounting Holes

Remove  the  paper  backing  from  the  mounting  template 
supplied.  Affix  the  template  to  the  duct  at  the  desired 
mounting  location.  Make  sure  the  template  lies  flat  and 
smooth on the duct. Center punch holes A and B. Drill the 
holes as indicated on the template.

[5.2.1] Sampling Tube Installation for Ducts Less 
Than 1

1

2

 Feet Wide (see Figure 2)

1. Remove the front cover.
2. Slide the plastic sampling tube into the housing bushing.
3. Align  the  holes  in  the  bushing  with  the  holes  in  the 

sampling tube. Make sure there are 6 exposed holes on 
the plastic sampling tube. Secure with the #8 self-tapping 
screw into the bottom of the permanent tube (shown in 
Fig. 1).

NOTE:

  For ducts greater than 1

1

2

  feet in width, refer to 

sections [5.4.1] and [5.4.2].

Figure 2. Plastic sampling tube
connected to duct smoke detector:

[5.3] Secure The Detector Housing To The Duct

Slide the foam gaskets over the tube bushings as shown in 
Figure 3. Use the two 1

1

4

 long sheet metal screws to screw 

the detector housing to the duct. 

CAUTION: Do not overtighten the screws.

D100-68-00                                                                                               2                                                                                            I56-1147-12R

[3] Figure 1. Exploded View Of Duct Smoke Detector Components:

FOAM

GASKETS

PLASTIC

SAMPLING TUBE

CONDUIT HOLES

DETECTOR

HOUSING

TERMINAL STRIP

DETECTOR

COVER

SAMPLING TUBE

FILTERS

COVER MOUNTING

SCREWS

PLASTIC SAMPLING TUBE

SELF-TAPPING SCREW

POWER BOARD

DETECTOR BOARD

Содержание INNOVAIR DH100ACDCP

Страница 1: ...esigned to operate on 24 VDC VAC 120 VAC or 240 VAC Alarm and supervi sory relay contacts are available for control panel interface alarm initiation HVAC control and other auxiliary func tions Auxilia...

Страница 2: ...Holes Remove the paper backing from the mounting template supplied Affix the template to the duct at the desired mounting location Make sure the template lies flat and smooth on the duct Center punch...

Страница 3: ...the end opposite the duct smoke detector 2 Slide the tube into the housing bushing that meets the air flow first Position the tube so that the arrows point into the air flow 3 Secure the tube flange...

Страница 4: ...air flow in the duct is 10 to 12 Space the additional holes as evenly as possible over the length of the tube NOTE This procedure should only be used as a temporary fix It is not intended as a perman...

Страница 5: ...ick or punk directly at the head to cause an alarm REMEMBER TO REMOVE THE PLUGS AFTER THIS TEST OR THE DETECTOR WILL NOT FUNCTION PROPERLY 6 1 3 Filter Replacement The filters do not substantially aff...

Страница 6: ...CONTACT MANUFACTURER NOTE THE SUPERVISORY RELAY NOW PROVIDES A FORM C CONTACT FOR CUSTOMIZED APPLICATIONS FOR STANDARD APPLICATIONS ONLY THE NO CONTACT IS USED POWER INPUTS ACCEPT 24 VDC 24 VAC 50 60...

Страница 7: ...s in the alarm state TROUBLE n a n a n a n a 9mA Max D100 68 00 7 I56 1147 12R 6 2 3 Sensitivity Tests 6 2 3 1 MOD400 or MOD400R Test After verification of alarm capability use the MOD400R test module...

Страница 8: ...n 2 0 VAC min 10 VAC min 20 VAC min Reset time with RTS451 03 to 0 3 sec 03 to 0 3 sec 03 to 0 3 sec 03 to 0 3 sec Reset time by power down 0 6 sec max 0 6 sec max 0 6 sec max 0 6 sec max Power up tim...

Отзывы: