D450-01-01

4

I56-298-09R

©2001 System Sensor

Three-Year Limited Warranty

System Sensor warrants its enclosed smoke detector base to be free from
defects in materials and workmanship under normal use and service for a
period of three years from date of manufacture. System Sensor makes no
other express warranty for this smoke detector base. No agent, represen-
tative, dealer, or employee of the Company has the authority to increase
or alter the obligations or limitations of this Warranty. The Company’s
obligation of this Warranty shall be limited to the repair or replacement of
any part of the smoke detector base which is found to be defective in
materials or workmanship under normal use and service during the three
year period commencing with the date of manufacture. After phoning
System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return
Authorization number, send defective units postage prepaid to: System
Sensor, Repair Department, RA #__________, 3825 Ohio Avenue, St.

Charles, IL 60174. Please include a note describing the malfunction and
suspected cause of failure. The Company shall not be obligated to repair
or replace units which are found to be defective because of damage,
unreasonable use, modifications, or alterations occurring after the date of
manufacture. In no case shall the Company be liable for any consequen-
tial or incidental damages for breach of this or any other Warranty,
expressed or implied whatsoever, even if the loss or damage is caused by
the Company’s negligence or fault. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limita-
tion or exclusion may not apply to you. This Warranty gives you specific
legal rights, and you may also have other rights which vary from state to
state.

Please refer to insert for the Limitations of Fire Alarm Systems

Содержание B401B

Страница 1: ...s 31 2 inch octagon box Min Depth 1 5 inches Operating Temperature Range 0 to 49 C 32 to 120 F Operating Humidity Range 10 to 93 Relative Humidity noncondensing Electrical Ratings includes base and detector System Voltage 12 24 VDC Maximum Ripple Voltage 4 Volts peak to peak Start up Capacitance 0 02 µF Maximum Standby Ratings 8 5 VDC Minimum 35 VDC Maximum 120 µA Maximum Alarm Ratings 4 2 VDC Min...

Страница 2: ...responding properly in the event of a fire For signal wiring the wiring between interconnected detectors it is recommended that the wire be no smaller than 18 gauge 1 0 square mm Wire sizes up to 12 gauge wire 2 5 square mm may be used with the base For best system performance the power and loop wires should be twisted pair and installed in separate grounded conduit to protect the loop from extran...

Страница 3: ...wiring has been checked the detector heads may be installed in the bases The shorting spring in the base will disengage automatically when the detector head is removed from the base DO NOT remove the shorting spring since it reengages as the detector head is turned into the base completing the circuit CAUTION Tamper resistance Feature Do not use the tamper resistance feature if the XR2 removal too...

Страница 4: ... 800 SENSOR2 736 7672 for a Return Authorization number send defective units postage prepaid to System Sensor Repair Department RA __________ 3825 Ohio Avenue St Charles IL 60174 Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modification...