D150-02-00

4

I56-598-03R

© 2001 System Sensor

Three-Year Limited Warranty

System Sensor warrants its enclosed smoke detector base to be free from
defects in materials and workmanship under normal use and service for a
period of three years from date of manufacture. System Sensor makes no
other express warranty for this smoke detector base. No agent, represen-
tative, dealer, or employee of the Company has the authority to increase
or alter the obligations or limitations of this Warranty. The Company’s
obligation of this Warranty shall be limited to the repair or replacement of
any part of the smoke detector base which is found to be defective in
materials or workmanship under normal use and service during the three
year period commencing with the date of manufacture. After phoning
System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return
Authorization number, send defective units postage prepaid to: System
Sensor, Repair Department, RA #__________, 3825 Ohio Avenue, St.

Charles, IL 60174. Please include a note describing the malfunction and
suspected cause of failure. The Company shall not be obligated to repair
or replace units which are found to be defective because of damage,
unreasonable use, modifications, or alterations occurring after the date of
manufacture. In no case shall the Company be liable for any consequen-
tial or incidental damages for breach of this or any other Warranty,
expressed or implied whatsoever, even if the loss or damage is caused by
the Company’s negligence or fault. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limita-
tion or exclusion may not apply to you. This Warranty gives you specific
legal rights, and you may also have other rights which vary from state to
state.

Please refer to insert for the Limitations of Fire Alarm Systems

Содержание B114LP

Страница 1: ...ox Min depth 1 5 inches Operating Temperature Range 0 to 49 C 32 to 120 F Operating Humidity Range 10 to 93 Relative Humidity Noncondensing Electrical Ratings includes base and detector System Voltage 120 VAC 60 Hz Relay Contact Ratings Resistive or Inductive 60 power factor load Form A 2 0A 30VAC DC Form C 2 0A 30VAC DC 0 6A 110VDC 1 0A 125VAC Start up Time 36 0 Seconds maximum After 60 second re...

Страница 2: ...r signal wiring the wiring between interconnected detec tors it is recommended that the wire be no smaller than AWG 18 However the screws and clamping plate in the base can accommodate wire sizes up to AWG 12 The use of twisted pair wiring for the power and loop is rec ommended to minimize the effects of electrical interference Wiring Instructions NOTE Refer the manufacturer s instructions for rel...

Страница 3: ...AC EOL SPECIFIED BY PANEL MANUFACTURER CONTROL PANEL SUPERVISORY RELAY ALARM RELAY SUPERVISORY RELAY ALARM RELAY EOL SPECIFIED BY PANEL MANUFACTURER NOTE ABOVE DIAGRAM SHOWS NFPA REQUIRED WIRING OF SUPERVISED SYSTEMS SCHEMATIC SHOWN BELOW FOR REFERENCE Figure 3 Wiring diagram for a typical 120VAC detector system Tamper resistance Feature NOTE Do NOT use the tamper resistance feature if the System ...

Страница 4: ... 800 SENSOR2 736 7672 for a Return Authorization number send defective units postage prepaid to System Sensor Repair Department RA __________ 3825 Ohio Avenue St Charles IL 60174 Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modification...

Отзывы: