7.15 I/O Alarm
***
IMPORTANT
***
The alarm output of the camera is a 3.3V TTL output relay, this means the alarm output with
either be in a low state (0V) or high state (3.3V).
Ensure an appropriate OPTO isolator relay is used to isolate the camera voltage to the triggering
device.
For example the HRM100 - Handy Rascal OPTO Isolating Relay
https://systemq.com/store/Item/GP-HRM100
Navigate to:
Configuration
>
Alarm > I/O alarm
The alarm output of the camera can be configured either low state (0V) or high state (3.3V)
when triggered.
When set to high, the alarm output will constantly be on low (0V) until the alarm output is
triggered, it will then increase the voltage to high (3.3V) until the trigger is removed. The opposite
will be configured when set to low.