TPMS TT02 User Guide
Sysgration Confidential
17
(2.4 PSI is 17 KPA, 83 KPA (Raw data) - 100 KPA = 17, more than the MIN limit 10KPA , so will display
negative character.)
If Fail
,
TT02 --> COMPUTER: "$
RPFAIL
#" 8 bytes
Read Temperature in Fahrenheit
for Sensor Format 2 (Advertising)
COMPUTER --> TT02: "
$RT#
", 4 bytes
If Success,
TT02 --> COMPUTER: "$RTVCCC#" 8 bytes
-
V = positive/negative characters, ‘-’ or ‘+’
-
CCC = Temperature value(Oct)
Ex: VCCC = “+075”, Temperature 75
°
F
VCCC = “-022”, Temperature -22
°
F
If Fail,
TT02 --> COMPUTER: "$
RTFAIL
#" 8 bytes
Read Battery
for Sensor Format 2 (Advertising)
COMPUTER --> TT02: "
$RB#
", 4 bytes
If Success,
TT02 --> COMPUTER: "$RBVVVV#" 8 bytes
-
VVVV = Battery value(Oct)
Ex: VVVV=3220, Battery is 3220mv
If Fail,
TT02 --> COMPUTER: "$
RBFAIL
#" 8 bytes
Read X – Acceleration
for Sensor Format 2 (Advertising)
COMPUTER --> TT02: "
$RAX#
", 5 bytes
If Success,
TT02 --> COMPUTER: "$RAXVOOOO.O #"12 bytes
-
V = positive/negative characters, ‘-’ or ‘+’
-
OOOO.O = X- Acceleration value(Oct)
Ex: VOOOO.O = “-0002.5”, X- Acceleration is -2.5G
If Fail,
TT02 --> COMPUTER: "$
RAXFAI
L#" 9 bytes
Read Z - Acceleration
for Sensor Format 2 (Advertising)
COMPUTER --> TT02: "
$RAZ#
", 5 bytes