background image

3-12. Initialization [Setting code: 656]

User can initialize the registered pagers and the transmitter.

But this is only applicable when the Gn, Pn of the pagers and the transmitter are

matched up together. 

2. Insert all pagers into the transmitter-charging dock. 

3. Press 6-5-6 and start initializing. 

1

6

2

7

3

8

4

9

5

10

4. How to Use GP-210RT

4-1. Call a pager

4-2. Attend to a call

Take one of the pager off from 

the transmitter-charging dock.

Return the pager to where the pager 

is given when the pager starts buzzing.

Place the pager back to the

transmitter-charging dock to recharge.

Press the pager number from 

the transmitter-charging dock 

to call the pager.

2

1

3

5

7

8

9

10

2

1

6

2

7

3

8

4

9

5

10

1. Press and hold 5 for about 10 seconds and
     the device becomes input standby mode
    

(Press and hold until it makes “Beep~~” noise)

2

- 12 -

Содержание Nttworks GP-210RT

Страница 1: ...Pager all in one GP 210RT USER MANUAL ...

Страница 2: ...er Number Setting 7 3 5 Other Settings 7 3 5 1 Pager Alarm Type Setting 7 3 5 2 Anti Theft Out Range Setting 8 3 6 Exit from Settings 8 3 7 RF Test Mode 9 3 8 Call Button ON OFF 10 3 9 Pager Vibration Intensity 10 3 10 Call Button Selection 11 3 11 Transmission Output Setting 11 3 12 Initialization 12 4 How to Use GP 210RT 12 4 1 Call a pager 12 4 2 Attend to a call 12 2 ...

Страница 3: ... DC 3 7V 180mA Lithium polymer battery W53 x L105 x H11 mm 35g Black Transmitter charging dock GP 210T Frequency Power source Antenna type Dimension Weight Color FSK 433MHz DC 8V 3A SMA type W140 x L149 x H40 mm 120g Black 2 Getting Started Plug the power at the rear of the transmitter charging dock and connect the antenna Rear of the transmitter charging dock Antenna connector Power connector Cal...

Страница 4: ...ve exit 6 Save exit Save exit on off Save exit Save exit Save exit Save exit 11 20 Setting Menu Code Number key Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise If you do not touch any key buttons for more than 25 seconds it is automatically exited from the settings 3 Settings Warning All pagers should be placed on the transmit...

Страница 5: ...p number from 1 to 31 and then press 6 to save and return to previous menu 3 2 Group Number Setting Setting code 632 User can prevent the signal interference with the neighboring Syscall systems by setting their own group number 1 2 3 4 5 6 Button Settingvalue 8 1 2 4 16 Save exit 2 Press 6 3 2 to enter the group number setting mode 1 6 2 7 3 8 4 9 5 10 1 6 2 7 3 8 4 9 5 10 ex Set group number 16 ...

Страница 6: ...ode 3 Set the ring time and then press 6 to save and return to previous menu Default 30 seconds 1 2 3 4 5 Button Settingvalue 40 5 10 20 1 6 2 7 3 8 4 9 5 10 Button Call time 30 sec 35sec 40 sec 60 sec 75 sec 1 5 2 10 3 20 4 40 5 Button Pn Gn number 1 1 2 2 3 4 4 8 5 16 1 2 3 4 5 31 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep...

Страница 7: ...ttings 3 5 1 Pager Alarm Type Setting Setting code 635 2 Press 6 3 5 to enter the other setting mode 3 Usercanpress1forvibrationand2forsound LED cannot be turned off Default Vibration Sound LED 1 2 3 4 5 6 Vibration Button Settingvalue Sound LED Save exit 1 6 2 7 3 8 4 9 5 10 4 Press 6 to save and return to previous menu 1 6 2 7 3 8 4 9 5 10 1 Press and hold 5 for about 10 seconds and the device be...

Страница 8: ...utomatically exited from the settings 2 Press 6 3 5 to enter the other setting mode 1 6 2 7 3 8 4 9 5 10 4 Press 6 to save and return to previous menu 1 6 2 7 3 8 4 9 5 10 3 Press the applicable button to set Anti theft and or Out range 1 6 2 7 3 8 4 9 5 10 1 2 3 4 5 Button Settingvalue Anti theft Out range 6 Save exit Anti theft function Alert on transmitter LED blink Sound Out Range function Ale...

Страница 9: ...ress 6 4 1 to enter the RF test mode 3 When the RF test mode turns on the relevant number displays in the order of call number of the pager frequency FND test version info Gn and Pn 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep noise 1 6 2 7 3 8 4 9 5 10 Pager No Frequency FND Test Version info Gn Pn 9 ...

Страница 10: ...ibration intensity setting mode 3 Press the applicable call button to set the vibration intensity 1 6 2 7 3 8 4 9 5 10 4 Press and hold 6 to save and return to previous menu 1 6 2 7 3 8 4 9 5 10 4 Press 6 to save and return to previous menu 1 6 2 7 3 8 4 9 5 10 1 6 2 7 3 8 4 9 5 10 1 Press and hold 5 for about 10 seconds and the device becomes input standby mode Press and hold until it makes Beep ...

Страница 11: ...nd the device becomes input standby mode Press and hold until it makes Beep noise 4 Press 6 to save and return to previous menu 1 6 2 7 3 8 4 9 5 10 User can set the transmission output level from 1 to 5 3 11 Transmission Output Setting Setting code 651 2 Press 6 5 1 to enter the transmission output setting mode 3 Press the applicable call button to set the output level 1 6 2 7 3 8 4 9 5 10 1 6 2 ...

Страница 12: ...5 10 4 How to Use GP 210RT 4 1 Call a pager 4 2 Attend to a call Take one of the pager off from the transmitter charging dock Return the pager to where the pager is given when the pager starts buzzing Place the pager back to the transmitter charging dock to recharge Press the pager number from the transmitter charging dock to call the pager 2 1 3 5 7 8 9 10 2 1 6 2 7 3 8 4 9 5 10 1 Press and hold 5...

Страница 13: ......

Отзывы: