SYSR86N Standard TCP/IP Reader Operation Manual
15
4.
86 Series- Xtive TAG
Xtive TAG
: Setup read mode for xtive RFI D tag.
Key
:
Only receive signal from xtive RFI D tag that pressed button.
Auto
:
Receive xtive RFI D Tag signal automatically.
I R Sensor
:
86N only receive xtive RFI D Tag signal when I R is triggered. Start read time is about 10
seconds.
Off
:
Turn off the function to read Active RFI D tag
Exciter I D
:
This parameter should use with SYRIS exciter, default values are “0” means disable. If this
function enable, reader will only receive tag’s signal which include set exciter ID.
Same
: Same card time. Default is 50 (50 x 0.1= 5 second)
Gain
:
Set Gain (1~13) to control reader’s read range.
Level 13 is the max range (default setting), Level 1 is the shortest read range.
RSSI
:
Adjust RSSI level (0~250) to filter TAG which have low RSSI signal in reader.
Ex. Set RSSI Level to 120, Reader will receive tag which RSSI are stronger than 120.
5.
86 Series- DI / DO Mode
DI / DO Mode Setting- RS485 Mode
( Communication interface have to sw itch into RS485)
DO1 :
Setup DO1 motion parameter
RS485
:
Control DO1 motion via RS485.
Touch Key
:
To activate DO1 by using touch panel keypad.
I R Sensor
:
To activate DO1 by using I R sensor.
Touch Key or I R Sensor
:
To activate DO1 by using touch panel keypad OR I R sensor. (Default)
DI 2/ DO3
: Setup the contact mode ( DI 2 or DO3 )
DI 2
:
Setup the contact does work as DI 2 (Default)
DO3 RS485
:
Setup the contact does work as DO3. I t is triggered via RS485.
DO3 Touch Key
:
The contact does work as DO3. I t is triggered by touch key.
DO3 I R Sensor
:
The contact does work as DO3. I t is triggered by I R.
DO3 Touch Key or I R Sensor
:
The contact does work as DO3. I t is triggered by touch key or I R.