15
Appendix 5
:
Using the SY210NT System
Q1
:
How to setting reader ID? What Reader ID and are Door
relate?
A1
:
SY210NT-V5 series oneself have no inside set up to read card system,
After expansion installs Reader can use reader card function. Controller ID and
Reader ID are setting [1] by factory default, so after setting Reader ID
expansion installs Reader, Otherwise can deliver failure because ID duplicates.
Reader module ID setting
Keypad
LCD display
Annotation
MENU
Login
EN
Password
[1234_ _ _ _]
Using numeric keypad input
password.
EN
Master OK
The Setup lamp signal is bright
Setup, Login success.
▼
*
2
System
EN
Controller
▼
*
1
Module
EN
Module
Auto detect
▼
*
1
Module
ID Setting
Reader module ID setting
EN
ID Setting
[ SYRDS1 / S5 / L5 ]
Using
▲▼
choice
module. (Note
1) module ID setting (Note 3)
EN
S / N [_ _ _ _ _ _ _ _]
Input serial number. (Note 2)
EN
Module ID
[1]
Input
Module ID.
EN
Module
ID Setting
Presses the EN key confirmation
ID setting.
CLR*3
2007/12/30 (Sun)
17:52:53
Setting success.
Reader ID setting step by step:
Note 1
:
The module can differentiate as follows.
READER
Proximity Card Reader. Have SYRDS1, SYRDS5,
SYRDL5 and MDWIE.
DIDO
Extend Module. Have MDDIDO-1S and MDDIDO-16.
Printer Module.
SYRDK5
Keypad Proximity Reader.
SYRDF5/F6
Fingerprint Reader.
SYRDT5
LCD Proximity Card Reader.
Note 2
:
User
can find the serial number on the packing box or serial number label at the
back of device.
Note 3
:
Readers ID alignment rule as follows,
Door 1
Door 2
Door 3
Door 4
External Reader
:
ID: 1
ID: 2
ID: 3
ID: 4
Internal Reader
:
ID: 5
ID: 6
ID: 7
ID: 8
Controller automatic detects Readers and Modules.
After setting Readers ID has to can take effect with
Controller connected. The setting step
by step as follows
:
Keypad
LCD display
Annotation
MENU
Login
EN
Password
[1234_ _ _ _]
Using numeric keypad input
password.
EN
Master OK
The Setup lamp signal is
bright Setup, Login success.
▼
*
2
System
EN
Controller
▼
*
1
Module
EN
Module
Auto detect
EN
Auto detect
Waiting ----- ID: xx
Controller automatic detects
display.
Find Module
:
[01]
OK
Found one module.
CLR*4
2007/12/30 (Sun)
17:52:53
Setting success.
Note 4
:
Controller can
automatic detects
Modules and Controller connected.
In normal
condition, if installed two devices ,then system demonstrate
Find
Module
:
[02] OK
.