SYRIS SY210NT Series
Quick User Guide Manual
Ver : 2.00
Control up to 4 doors with in/out reader
Baud rate 2,400 - 115,200 bps
Страница 1: ...SYRIS SY210NT Series Quick User Guide Manual Ver 2 00 Control up to 4 doors with in out reader Baud rate 2 400 115 200 bps ...
Страница 2: ...tructural drawing here for user to get familiar with the SY210 serial controller operation procedure The first step is to execute the white box Login procedure to enter dark gray box main menu and light gray sub menu please refer the diagram key and the direction of arrow the function description of sub menu will be introduce at below document ...
Страница 3: ...orp 2 Overview I t e m Contents Page 01 Attention matter 3 02 Login logout steps 3 03 Setup module setup reader 4 04 Add delete edit card 8 05 Add and delete fingerprint 12 06 Setup controller ID when multiple controllers online 18 07 Procedure control setup open door button 20 ...
Страница 4: ...ID all set to 1 Please setup ID first before connect multiple controller or reader to avoid ID repeat cause communication failure Please refer the reader ID setup method of page 5 Setup module And about controller ID setup please refer page 17 Setup controller ID 02 Login logout step The SY210NT controller needs to complete the login step to enter function menu The controller will automatically lo...
Страница 5: ...splay date and time Setup light goes out complete logout step The below steps pre set in login status 03 Setup Module setup reader After install controller and reader the user needs to setup reader ID and scan communication status from controller plug play to normal transmit the I O data The next diagram is System main menu table and the gray part is the step operation range ...
Страница 6: ...le ID annotate 3 EN Change ModuleID Setup complete back to item Annotation 1 Module type Annotation 2 The user can find the serial number sticker from card reader package or machine back Annotation 3 Card reader ID arrange rule READER General proximity reader including SYRDS1 S5 L5 DIDO Digital contact expand module including MDDIDO 1S MDDIDO 16 PRINT Printer module SYRDK5 Keypad proximity reader ...
Страница 7: ...tus the display module amount will match with the practical installed module amount In another word the scan result should display Find 04 OK If the display amount is unusual please refer the below table to eliminate the issue Unusual situation Scan display 00 or display less amount Possibility The communication is not correct or repeat ID Eliminate method Please confirm the communication again Th...
Страница 8: ... Serial or Add Card By No The edit card function is for setup card enable disable Status Setting passage application group APP Setting card password PIN Setting and anti pass back function APB Setting Delete card can separate into Del Card by No or Delete All Card The next diagram is the Card main menu table and the gray part is the step operation range ...
Страница 9: ...t from 0001 and continue to proximity un used card the card number will automatically add up If there are several cards have been deleted in one serial card numbers it will be fill in the card number which has been deleted first For example the already add card number from 0001 to 0010 which the 0005 has been deleted lately and next time when user use automatically add card function it will fill i...
Страница 10: ... the user co operate with SYW95A door access manage software to proceed setting the description of each function is at next page Passage Application Group APP Setting Able to setup card holder group max 16 groups Co operate with SYW95A door access manage software can setup the passage timer and passage door Card password PIN Setting Install keypad proximity reader can setup card holder personal pa...
Страница 11: ...rd Process 2 Del Card Process EN Del Card By No Delete card by no mode EN Del Card No 0001 Enter the card number which wants to delete EN Del Card By No Card has been deleted back to item Delete All Card Delete all card mode EN Delete No Confirm delete or not Delete Yes Choose Yes EN Delete OK All cards have been delete CLR Delete All Card Back to item ...
Страница 12: ...ace by fingerprint or fingerprint corresponding to card to attend the fingerprint control function The setting of fingerprint corresponding to card is for one card corresponding to ten fingerprints out suggestion is to use the Syris fingerprint manage software SYFPM In the follow steps we are going to introduce how to add delete fingerprint and setup card replace by fingerprint the next diagram is...
Страница 13: ...Enter the fingerprint number which wants to add EN Add Finger Press finger when F5 light flashes and produce sound annotate Delete Fingerprint Enter key LCD display Reference MENU System 3 Finger Print Fingerprint item EN Finger ID 1 Select fingerprint module ID EN Add Finger Add fingerprint mode Delete Finger Delete fingerprint mode EN Delete By No Delete card by number mode EN Finger No 0001 Ent...
Страница 14: ...d card and replace by fingerprint here Press finger Ins Card 0001 Card replace by fingerprint Annotation The attention matter of press fingerprint In order to maintain the fingerprint identify rate in standard value please pay attention on the below introduction of press fingerprint The fingerprint sampling method is to get many minutiae extend from the fingerprint center as the right image the cr...
Страница 15: ...press the fingerprint in the effective proximity area X Error the fingerprint only touch the effective proximity area lightly and can not be identify X Error the fingerprint center not locate in effective proximity area properly the sampling is not enough X Error the finger is not press equally in the effective proximity area less contact area and can not be identify X Error the finger position is...
Страница 16: ...an not identify the status The mainly reasons of common fingerprint identification failure 1 The finger moved or pressed incorrectly Please follow the description above to enroll fingerprint correctly 2 Avoid wet and oily finger especially rainy day or the personnel who touch grease Please wipe the finger with towel then press fingerprint 3 The finger too dry to display the clearly fingerprint Ple...
Страница 17: ...ler ID when multiple controllers online When multiple controllers operate online the ID of each controller needs to setup separately to avoid ID conflict and cause communication abnormality The next diagram is the System Process main table and the dotted line part is the operation range of this step ...
Страница 18: ...orp 17 Setup Controller ID Enter key LCD display Reference MENU System EN Login 5 System Process EN APBLevel Setting Control ID Setup controller ID item EN Control ID 0001 Enter the controller ID number 1 99 which wants to assign EN Control ID Complete the controller ID setting ...
Страница 19: ...rol the program can control functions to attain to the different functions demand Next diagram is the example of setup press button to open door method The DO1 of SY210NT TSN connects to electric lock and the DI1 connects to the open door button Therefore the action of press button to open door can be done though the setting of procedure control ...
Страница 20: ...ion of setup open door action EN Event CardSenc 12 Event DI On We connect the open door button to controller DI1 so select DI On for input signal EN Event ID 9 Select the event source module setup module ID 9 which mean the signal source is controller EN Event Ch 01 Select event channel this case setup open door button connect to controller DI1 so choose channel 1 EN Event Delay 00 Event delay tim...
Страница 21: ...Action Open Setup receive open door signal the Realy action is open EN Action Ch 01 Select the action channel output byDO1 EN Action Setting Complete the action setting to be continued Procedure Control setup open door button Enter key LCD display Reference Method Time Setup action time EN Method Alway Setup time mode 2 Method Sec Choose count by second EN Method Time 003 Setup time 003 three seco...