![Synxcom SM19202FP Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/synxcom/sm19202fp/sm19202fp_user-manual_1421422015.webp)
Installation
15
User’s Manual - SM19202 Fast Poll Modem
DIP Switches
Switch Settings
ON
OFF (Default)
S1-5: Auto RTS
Enabled
Disabled
S1-6: Transmit Carrier Control
(SM19202FP-K only)
Radio Push-to-Talk option
Normal Leased Line
S1-7: 2- or 4-wire leased line
2-wire half duplex
4-wire full duplex
S1-8: Transmitter Impedance
Controlled by RTS
600 ohms
S1-9: Remote Digital Loopback
Enabled
Disabled
S1-10: Test Only (Reserved)
Factory Test only
Normal Operation
DIP Switch S2
S2-1 to S2-3: Transmit Output Level
From -14 to 0 dBm (see Table 2-5)
S2-4: Modem Receive Dynamic Range
-10 to -43dBm
0 to -30dBm
S2-5: TX Cable Equalizer
Enabled
Disabled
S2-6: RX Cable Equalizer
Enabled
Disabled
S2-7: Anti-streaming
Active
Inactive
S2-8: RTS-CTS Delay (Bell 202T only)
33 msec
8 msec
S2-9: Forced RTS ON
Force RTS & Carrier to ON
Controlled by RTS signal
S2-10: Re-Train Enabled (19200 bps only)
Enabled
Disabled
DIP Switch S3
S3-1: RS-232 Interface operation
Both S3-1 and S3-2 are set to OFF
S3-2: RS-485, 4-wire interface
2-wire interface
S3-1 = ON, S3-2 = OFF
S3-1 = OFF, S3-2 = ON
S3-3: RS-485, Receiver Termination
High Impedance
120 Ohms
S3-4: Not Used
S3-5: Receiver Termination
600 Ohms (Default)
High Impedance
S3-6: Signal Ground and Chassis Ground
Connected Together
Open
S1-1, S1-2, S1-3
−−−−
Modem Data Rate
S1-1, S1-2, S1-3: Select the modem speed per Table 2-2