Synway Information Engineering Co., Ltd
Figure 2-17 Buckling Motherboard
Attention: The steps to uninstall the spring steel buckle are just contrary to install.
Step 7: Set up an application environment.
Connect the line from the NT port in central office with the TE port and the line from the TE port
in central office or an ISDN phone with the NT port to set up an application environment. If the
TE port in central office or the ISDN phone requires the NT port to provide feed, you should
turn on the PSW slide switch of the corresponding channel as well as the slide switch
corresponding to Port1 or Port2 on the module NT200.
Step 8: Connect the clock synchronization line.
Note: Skip this step if there is no need to get clock synchronization for multiple boards.
The clock synchronization line is
h
motherboards or connect BRI16 fu
s (e.g. digital trunk
s in
ferent boards. (Note: The
ds and daughterboards is achieved by the
they are connected with a clock
atically with the driver, please execute
hronization configuration.
lockconf
the
premise that the driver h
See
used to connect more than one BRI16 full-lengt
ll-length boards with other kinds of board
boards or analog boards) so that these boards can use a same clock to reduce the error
faxing and to ensure the accuracy of data transmission between dif
synchronization of BRI16 full-length motherboar
backboard, not the clock synchronization line.)
After connecting a clock synchronization line with two boards, you have to make proper
configurations on it to let these two boards work synchronously. Follow the steps below.
1. For two BRI16 full-length motherboards, when
synchronization line, powered on and loaded autom
the following command to activate the clock sync
#>echo 12 > /sys/module/bri16/parameters/clockconf
2. For a BRI16 full-length motherboard and a board of other model (such as a digital trunk
board), when they are connected with a clock synchronization line, powered on and
loaded automatically with the driver, please execute the following command to activate
the clock synchronization configuration.
#>echo 1 > /sys/module/bri16/parameters/c
Note: If the file /sys/module/bri16/parameters/clockconf does not exist, you may try to use
/sys/module/bri16/clockconf to replace /sys/module/bri16/parameters/clockconf on
as been loaded.
Figure 2-18 below.
Synway BRI16 Full-length Board Hardware Manual (Version 1.0)