INTRODUCTION 

 

 

 

The CONDUCTOR 420 Controls provide flexible and concise solid-state power control for inductive and resistive loads 

below control current rating.  They are used with Syntron® electromagnetic vibratory equipment including light-duty 
feeders and electromagnetic type bin vibrators.  
  
The  standard  CONDUCTOR  420  Control  features  adjustable  soft-start,  50/60  Hz  operation,  and  half-wave  operation. 
CONDUCTOR 420 Controls also feature minimum and maximum operation windowing adjustments (permitting greater 
linearity for specific applications).  
  
The control board contains a manual potentiometer for controlling output from the vibrating equipment.  If desired, a 0-5 
volt Analog input signal may be applied in the place of the Main Control dial at H1. The 0-5 VDC input is transformer 
isolated from the power line.  See “Setup Procedure” for additional information on these features.  

  

INSPECTION AND LONG-TERM STORAGE  

  
Upon receipt, unpack and inspect the control for any damage that may have occurred during shipment.  If damage is 
found, contact the shipping carrier and Syntron Material Handling immediately.  
  
If the control must be stored for an extended period of time, it must be stored indoors in its original shipping container, in 
an area safe from water damage.  Plug all openings in the control box to prevent dirt, rodents, and insects from entering.  
Syntron Material Handling advises placing a corrosive preventive inside the control box.  Be careful not to drop the control 
because the impact could damage components.   

  

INSTALLATION  

 

 

 While installing the control, be careful to maintain its NEMA or IP rating integrity.  Power supply voltage and frequency 
requirements are designated on the control nameplate.  If remote mounting is necessary, the control should be installed close 
to the equipment where it is easily accessible and within sight of the operator.  Installation on a wall in a vibration-free 
location is recommended.  Ambient temperature should not exceed 105ºF (40ºC).  

   

 WARNING: The power supply voltage and frequency must match the requirements  

 

 

 

 

indicated on the nameplate. 

 WARNING: The electrical power supply to the Syntron Material Handling-supplied control must   

 

 

be made through a customer-supplied safety disconnect switch mounted next to the  

 

 

 

 

control. All installation wiring must adhere to local electrical codes. 

 

 

WARNING:  The control must be properly grounded. 

 

 

  

CAUTION: Follow the wiring diagram furnished with the control when making electrical 

 

connections.

 

 

 
CAUTION:  A fuse (maximum of 20 amps) must be installed between the power 

supply and the printed circuit 

board connection.  Syntron Material Handling recommends

 a “Fast Acting” type fuse. 

 

Содержание Conductor 420

Страница 1: ...Listed File No E195547 Input 480 VAC 50 60 HZ Operating range 380 480 VAC 20 AMP MAX OUTPUT W 25 AMP FUSE Output 0 90 of Input Voltage Service Instructions Conductor 420...

Страница 2: ...on Page Safety Instructions 4 Introduction 5 Inspection and Long Term Storage 5 Installation 5 Operation 6 Setup Procedure 6 Maintenance 9 Troubleshooting 9 Wiring Diagram 10 Recommended Spare Parts 1...

Страница 3: ...mber _________________________ 3 Quantity of parts required 4 Syntron Material Handling part number from manual 5 Description of part 6 Shipping instructions Syntron Material Handling reserves the rig...

Страница 4: ...red during shipment If damage is found contact the shipping carrier and Syntron Material Handling immediately Read instructions carefully Be familiar with the controls and proper use of the unit Do no...

Страница 5: ...tainer in an area safe from water damage Plug all openings in the control box to prevent dirt rodents and insects from entering Syntron Material Handling advises placing a corrosive preventive inside...

Страница 6: ...tage can cause a vibrator to vary its vibration The line voltage compensation feature adjusts the control s output to help compensate for fluctuations in the supply voltage Use the accompanying chart...

Страница 7: ...he desired output ramp up time from 0 10 seconds at the start up of the feeder Fully Counter Clockwise 0 second ramp up time Fully Clockwise 6 second ramp up time Factory Default Fully Counter Clockwi...

Страница 8: ...ct between terminals 6 and 7 of TB2 iii OFF De activate both dry contacts STATUS LEDs RUN Indicates the board is functional and all input conditions are met DIRECT Is ON when the inhibit jumper is con...

Страница 9: ...VDC signal to terminals 11 12 if jumper is across terminals 5 6 No AC line voltage No AC voltage on TB1 Contacts or jumper missing at TB2 between 6 and 7 MAX pot turned full counter clockwise Feeder...

Страница 10: ...10 WIRING DIAGRAM...

Страница 11: ...DESCRIPTION PART NUMBER Potentiometer 100K w cable 7200 040 011 PC Board Assembly 7200 039 001 Thyristor Module 7200 040 006 Disconnect Switch 30A 7200 040 008 Fuse 2A thru 20A FAST ACTING 600V TYPE C...

Страница 12: ...12 BOX LAYOUT...

Страница 13: ...13 BOX DIMENSIONS...

Страница 14: ...Hwy 145 South Saltillo Mississippi 38866 Phone 662 869 5711 Fax 662 869 7493 Toll Free 800 356 4898 info syntronmh com Changshu 2 Road No 1 Changshu Export Processing Zone Changshu Jiangsu China 21551...

Отзывы: