Sequence 8 - Testing Procedures
Before you start this test, make sure that all knobs on the Sequence 8
have been rotated fully counter clockwise and that all 3 toggle
switches (Hold Hard, Clock Switch, Random) are in the down position.
—TESTING CV OUTPUTS—
When you first turn on the Sequence 8 it
should
be running on its
internal clock. Let’s make sure that all 3 CV Outputs are working
correctly.
Begin by plugging in a cable into the Sequence 8’s CV 1
Output and plug the other end of the cable into the 1V/Oct Input on an
Oscillator, and make sure to monitor the output of the oscillator.
Since all 8 of the sequence knobs are rotated fully counter clockwise
and the CV 1 input is set fully counter clockwise, you should get a
stable tone out of your Oscillator.
Rotate Step 1’s knob fully clockwise and leave the CV 1 attenuator set
fully counter clockwise. You should still get a stable tone out of your
Oscillator when it passes the voltage for Stage 1. If the Oscillator
changes pitch even though the CV 1 Attenuator is turned down all the