Global Controls
Stop / Loop Switch
●
(Global Loop):
○ The global Loop control is different than the channel Loop. While the channel
Loop allows each channel to self-cycle independently, the global Loop triggers
channel one when channel four’s cycle is complete.
○ If individual channels are looped AND the global Loop is engaged, each channel
will self-cycle until it is retriggered by the previous channel’s end of cycle.
○ If all channels are set to AR of AD when the switch moves from Stop to Loop,
nothing will happen until one of the channels receives a trigger or one of the
channel switches is set to Loop (even if momentarily).
●
(Stop):
○ Stops channel four’s end of cycle from internally triggering channel one.
ALL A: CV over all attack cycles
● Affects the length of attack of all four envelopes. The input signal is additive to the
physical position of the attack potentiometers in each channel. A four-second attack
cycle can be accomplished by turning the ATTACK pot on a channel fully clockwise and
adding 5V to the ALL A jack.
ALL D/R: CV over all decay / release cycles
● Affects the decay / release of all four envelopes. The input signal is additive to the
physical position of the D/R potentiometers in each channel. A four-second D/R cycle
can be accomplished by turning the DEC/REL pot on a channel fully clockwise and
adding 5V to the ALL D/R jack.