Add Control (R)

: The right Control key will be sent together with the 

character programmed. 

Parameter Label

Key Type / Status Label

Two Hexadecimal Labels

"Validate" Label

• 

Add Alternate (R)

: The right Alternate key will be sent together with the 

character programmed. 

For example, to program the Prefix Code to be “Ctrl-Shift-B”, “C”, the 
programming sequence should be:  

1) “Prefix Code” label  
2) “Add Control (L)” label 
3) “Add Shift” label 
4) “4” of the hexadecimal digit 
5) “2” of the hexadecimal digit 
6) “4” of the hexadecimal digit 
7) “3” of the hexadecimal digit 
8) “Validate” 

Note:

 In internal representation, characters that are specified with either scan code 

or associate key status, occupy two normal character space each. So the maximum 
number of characters can be configured for a string parameter will decrease, if these 
character specifications are used. 

 

For example, to configure the Prefix Code to be “AB”, the “Prefix Code” label is 
first read, and then the hexadecimal digit labels “4”, “1”, “4”, and “2” are read, and 
finally, the “Validate” label to complete the setting. 

9.5  Exit Configuration Mode 

9.4.3  Key Type/Status Setting 

Both the “Update”, and the “Exit Setup without Changes” labels will exit the 
scanner from configuration mode when they are read. These two labels differ in 
whether to keep the new settings on the scanner or not, as their names suggest. The 
scanner will respond with 6 beeps and restart itself, if either label is read. 

The key type/status is specified in character basis. Each character programmed is by 
default of 

Normal

 key type. A character of normal key type can have associate 

status settings (add Shift/Control/Alternate).  

Whereas a character of 

Scan Code

 type may not have any associate key status 

settings. 

• 

Normal Key Type: 

When this label is read, the scanner will assume the 

following hexadecimal digits are the ASCII code of the character being 
programmed. And it will also clear all the associate key status settings made 
to the current character. 

• 

Scan Code

: When this label is read, the scanner will assume the following 

hexadecimal digits are the scan code value of the character being 
programmed. 

• 

Add Shift

: The Shift key will be sent together with the character 

programmed. 

• 

Add Control (L)

: The left Control key will be sent together with the 

character programmed. 

• 

Add Alternate (L)

: The left Alternate key will be sent together with the 

character programmed. 

 

34

 

33

Содержание CIPHER 1160

Страница 1: ...uency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in...

Страница 2: ...1 Configuring 1160 1260 14 5 1 1 Activate Bluetooth Serial Port Interface 14 5 1 2 Authentication PIN Code 14 5 1 3 Device Name Broadcasting 14 5 1 4 Update Settings 15 5 1 5 Timeout 15 5 2 Configuri...

Страница 3: ...9 5 Exit Configuration Mode 34...

Страница 4: ...today but also can fulfill your long term needs The main functions and features provided on the 1160 1260 are listed below 2 1 Power Up the 3660 Base Station Barcode Readability Most popular barcode s...

Страница 5: ...er will be disconnected To charge your scanner just place it on the base The LED on the top of the scanner will flash RED whilst it charges When the battery is fully charged around 4 hours from comple...

Страница 6: ...a setup barcode is read If the particular setup parameter needs more than one read the scanner will only issue a short beep to indicate that there are more setup barcodes needed to complete the curre...

Страница 7: ...symbology can be individually enabled or disabled The scanner will automatically discriminate and recognize all the symbologies that are enabled The supported barcode symbologies are listed below Lase...

Страница 8: ...ex Telex 122Keys 4 1 2 Keyboard Style Alphabets Keyboard layout style can be selected There are three options to this setting default layout US or English style AZERTY layout and QWERTZ layout This se...

Страница 9: ...ta Bits The supported baud rate parity and data bit are listed below Baud Rate 115200 38400 19200 9600 4800 2400 1200 600 Parity None Even Odd Data bit 8 7 4 2 2 Flow Control The user can further conf...

Страница 10: ...ring 1160 1260 Before starting the configuration the scanner must be powered up If you have not done so please follow the procedures described in section 2 2 Power Up the 1160 1260 to power up the sca...

Страница 11: ...e mode by pulling the trigger And again the scanner will stay active for another one minute waiting for connection before it goes to power down mode again Once there is a successful connection the sca...

Страница 12: ...160 1260 you can leave Secure Connection checked Click Apply and OK Click OK to go back to My Bluetooth Places 18 Wake up 1160 1260 by pulling the trigger just in case it falls asleep Double click Fin...

Страница 13: ...see that there is only one service available on SW3000006 The service name is COM1 on SW3000006 which is the Bluetooth Serial Port service Double click on the service This will start the connecting p...

Страница 14: ...al scan has a high probability of decoding as a valid but shorter 2 of 5 codes known as short scan To prevent this kind of undesired reading the Code Length settings can help to insure that the correc...

Страница 15: ...data being transmitted Checksum Transmission If this parameter is enabled the checksum character will be included in the data being transmitted Checksum Transmission If this parameter is enabled the...

Страница 16: ...settings are configured on a character base That is a specific character is to be substituted by another character The character substitution is performed on every occurrence of the characters specifi...

Страница 17: ...ormat if parameters other than those pertaining to editing format are read the editing format under configuration will be aborted User must restart the configuration again by selecting editing format...

Страница 18: ...essed by a particular editing format that format must be enabled The editing formats can be enabled or disabled individually 8 10 Exclusive Data Editing If this parameter is enabled all data read by t...

Страница 19: ...special parameters multiple reads are required to complete the setting The scanner will respond with a short beep if the configuration of the parameter is still not complete These parameters usually r...

Страница 20: ...Status Setting Both the Update and the Exit Setup without Changes labels will exit the scanner from configuration mode when they are read These two labels differ in whether to keep the new settings on...

Отзывы: