Wiring Notifications

 

 

When  using  a  solenoid  valve  or  other  inductive  loads,  please  apply  an  arc 

extinguisher  or  RC  voltage  dependent  resistor  RC  to  ensure  the  life  of  the 

contact points. Advantages of the arc extinguisher: 

1)  Extend the life of electrical contacts. 

2)  Reduce the sparks from the contact points. 

3)  Prevent the inductive loads from interferences caused by back EMF. 

4)  Restrain the impulse voltage. 

 

If the server line you are using is not a standard Syntec cable, please check all 

the  terminals  and  make  sure  they  are  connected  properly  before  running  a 
test. The wrong wiring will lead to the controller output command error and 

cause malfunctioning. 

 

MPG  terminal’s  +5V  output  capacity  is  200mA  and  it  is  only  for  a  single 

external  hand  wheel.  Do  not  connect  it  with  other  loads  or  it  might  cause 
malfunction due to the lack of drive capacity. 

 

The  external  24V  power  supply  used  in  wiring  should  be  certificated  and 

protective  to  avoid  the  malfunction  caused  by  wiring  mistakes. 

(Recommendation  standard

fulfill  requirements  of  both  EN60950  and 

UL1950) 

 

Please crimp or weld the wire connections while doing the wirings.   

 

In case of the use of Ethernet, to prevent the internet congestion and noise, the 

CAT5e or CAT6 cable are recommended.   

 

Do  not  use  counterfeit  terminal  strips.  Those  terminal  strips  cannot  provide 

overall  protection  for  the  system.  The  quality  is  also  not  guaranteed  and 
prone to cause electrical control problems of the machine tools. 

 

Grounding Directions: 

1)  The length of the grounding wire should follow the electrical equipment 

regulations. The shorter the better. 

2)  The grounding wire of the controller should be separated from those with 

large current loading such as electric welders or high frequency motors.   

3)  Please  refer  to  the  pictures  below  when  the  controller  is  grounded  with 

multiple electrical control devices. Do not make it a loop. 

 