TECHNICAL REFERENCE
PAGE
|
36
Auxiliary Power Connector
– provides an optional 30 VDC @ 350 mA source for powering the UC-2000
Controller. An auto-resetting solid-state fuse limits line current. Connector power is active after 30 VDC is
applied to the laser.
Technical reference
Use information in this section as a technical reference for you Series 48 lasers.
This section contains the following information:
•
Technical overview – briefly describes Series 48 technology, design RF power supply and basic
optical setup.
•
Controlling laser power – explains various aspects of Series 48 control signals.
•
DB-9 connections – describes input/output signals and specifications for the side mounted DB-9
connector.
•
DC power/ DC sense cables -provides information about DC power and voltage sense cables.
•
Integrating Series 48 safety features – describes how to integrate Series 48 safety features into
your automated control system.
•
Series 48 general specifications – provides specifications for the Series 48 laser.
•
Model 48-1, 48-2, and 48-5 package outline drawings – illustrates laser package and mounting
dimensions for Keyswitch and OEM 48-1 (10, 25, and 50-watt lasers, respectively.
•
Series 48 packaging instructions – illustrates how to package the Series 48 lasers for shipment
using NOVANTA-supplied packaging materials.
Technical overview
The Technical overview section includes subsections:
•
Introduction
•
Plasma section
•
Optical resonator
•
Control circuitry
•
Optical setup,
•
Faults, cooling, and DuoLase®
Caution: Possible Equipment Damage
Small amounts of contaminants on the laser’s output window (or on any optic in the beam path) can
absorb enough energy to damage the optic. Inspect all beam delivery optics periodically for signs of
contaminants and carefully clean as required.
In dirty environments, purge laser optics using filtered air or nitrogen to prevent vapor and debris
from accumulating on optical surfaces.
Содержание Novanta 48 Series
Страница 1: ...ENGINEERED BY SYNRAD 48 Series User Manual...
Страница 21: ...SERIES 48 1 LABEL LOCATIONS PAGE 21 Series 48 1 label locations Figure 2 1 Hazard label locations 48 1 example...
Страница 22: ...SERIES 48 2 LABEL LOCATIONS PAGE 22 Series 48 2 label locations Figure 2 2 Hazard label locations...
Страница 23: ...SERIES 48 5 LABEL LOCATIONS PAGE 23 Series 48 5 label locations Figure 2 3 Hazard label locations...
Страница 29: ...EUROPEAN UNION EU REQUIREMENTS ROHS COMPLIANCE PAGE 29 Figure 2 2 Declaration Document...
Страница 40: ...SETTING COOLANT TEMPERATURE PAGE 40 Table 4 1 Dew Point Table F temperatures...
Страница 63: ...MODEL 48 1 GENERAL SPECIFICATIONS CONTINUED PAGE 63 Model 48 1 general specifications continued...
Страница 65: ...MODEL 48 2 GENERAL SPECIFICATIONS CONTINUED PAGE 65 Model 48 2 general specifications continued...
Страница 69: ...TECHNICAL DRAWINGS PAGE 69 Figure 4 15 Model 48 2 package outline and mounting dimensions 2 of 2...
Страница 70: ...TECHNICAL DRAWINGS PAGE 70 Figure 4 16 Model 48 5 package outline and mounting dimensions...
Страница 71: ...TECHNICAL DRAWINGS PAGE 71 Figure 4 17 Model 48 1 packaging instructions...
Страница 72: ...TECHNICAL DRAWINGS PAGE 72 Figure 4 18 Model 48 2 packaging instructions...
Страница 73: ...TECHNICAL DRAWINGS PAGE 73 Figure 4 19 Model 48 5 packaging instructions...
Страница 74: ...TECHNICAL DRAWINGS PAGE 74 Figure 4 20 FLMK 1A 10W fan shroud packaging instructions...
Страница 82: ...OPERATIONAL FLOWCHART PAGE 82 Operational flowchart Figure 5 1 48 series operational flowchart...
Страница 85: ...STATUS LEDS PAGE 85 Status LEDs Table 5 3 48 series Input Output LED Status Signals...
Страница 88: ...INDEX This page is intentionally left blank...