Diode Pointer Quick Start Guide

Important

Note:

Diode Pointer Unpacking and Installation Preparation:

Read all 

Danger, 

Warning, 

Caution terms, symbols, and instructions located 

on our website. The diode pointer provides a safety measure by enabling operators 

to monitor the location of the CO

2

 beam. Reference the Diode Pointer Specifications 

located on our websit

https://www.synrad.com/products/accessories/visible-di-

ode-pointer.

1.

  Remove the Diode Pointer from it’s packaging and set aside. Take note of the box contents.

The pointer has both near and far field adjustments set at the factory. If alignment is still required after 

installation, see the following sections for guidance. If your SYNRAD® laser is shipped with a Diode Pointer 

installed, it is also factory pre-aligned and ready for operation.

2. 

   Upon arrival, inspect all shipping containers for signs of damage. If you discover shipping damage,  

 

document the damage (photographically if possible), then immediately notify the shipping  

 

 

carrier (responsible party for any transportation damage) and SYNRAD. 

3.

  Remove the two dust covers. One of the covers is on the front of the Diode Pointer face, the other is on  

 

the back. 

Click here to see an instructional video

, also reference the following figures.

Failure to 

remove can 

damage the 

laser!

1.1

   Collect the required tools per the Installa-   

 

tion Instructions included in your box and    

 

remove the two dust cover(s) one in front    

 

and another in the back.

Warning

Serious 

personal 

injury

Assure the laser and the diode pointer are 

turned off during install.

Содержание Diode Pointer

Страница 1: ... following sections for guidance If your SYNRAD laser is shipped with a Diode Pointer installed it is also factory pre aligned and ready for operation 2 Upon arrival inspect all shipping containers for signs of damage If you discover shipping damage document the damage photographically if possible then immediately notify the shipping carrier responsible party for any transportation damage and SYNR...

Страница 2: ... near far field adjuster screws accessible Tighten the four screws with the ignition wrench 4 1 Hanging the Diode Pointer onto the laser faceplate providing power to the unit Warning Serious personal injury Do not stare directly into the red laser light emitted from the Diode Pointer OR the laser The light is intense enough to injure the eye with exposure Always wear eye protection CO2 laser emits...

Страница 3: ... on the cable connect the cable by the 5 VDC jack reinstall the hex nut on the outside of the faceplate affixing the cable Re install the face plate and refer to the prior page for mounting 6 2 Locate the laser s 5VDC jack shipped with your unit Remove the hex nut on the cable and set it aside 6 3 Insert the cable through the face plate power port and re install the hex nut 6 4 Connect the cable t...

Страница 4: ...C 100Ma On Off Power supply 7 If your laser does not provide a power connection for the Diode Pointer use the plug from the supplied wall plug transformer into the 5 VDC jack on the side of the pointer 8 Press the On Off switch The red LED below the switch illuminates to indicate the pointer is on and laser diode emission should be visible ...

Страница 5: ... 20 watts Note the lasers coincidence with the diode pointer Near field distance adjustment screws moves the beam vertical and diagonal A Near field Approx 30cm 30cm 9 1 Example of laser and diode pointer coinci dence within 0 1mm Diode Pointer install and setup complete 9 1 Example of a diode pointer that requires adjustment 10 If the beam requires adjusting insert the two Allen wrenches included...

Страница 6: ...did in the prior steps Power on and fire the CO2 laser again at low power approxi mately 10 20 watts until you get a good burn image on the thermal card and observe the diode point ers coincidence with the beam You should have good coincidence by now If not see the above Im portant note before proceeding to the next section B Far field Approx 3 10m Important Note Since adjusting the beam affects b...

Страница 7: ...inter Rotate the pointer mounting plate 180 degrees re tighten the screws holding mounting plate to pointer Re install and tighten the two screws If the pointer is all the way to its limit in the slots it may be necessary to rotate the mounting plate in relation to the pointer housing 15 Assure the laser is off Remove the diode pointer from the laser 16 Refer to the figures below and remove the tw...

Страница 8: ... erance of alignment Anything more precise and accurate is desirable but not necessary Final accuracy and precision alignment is completely dependent on the final use of the pointer Most articulated arm applica tions require 100 micro radians while a simple lens system requires only 1 milliradian The outside tolerance or acceptable misalignment is 1 milliradian or 1 mm at 1 meter Congratulations T...

Отзывы: