cvgt MM User Manual
11
Copyright © 2014 Synovatron Limited. All rights reserved. (Rev 0 February
2014
)
Fitting Instructions
The cvgt MM can fit in any one of the four positions available in the
ModuleModule Model 041 frame. The power connection from the cvgt MM is
a keyed 9-way Molex socket that plugs into the Model 041 frame’s distribution
board.
The cvgt MM only uses ±15V and GndQ (0V); the other 6 pins are not
connected.
Please ensure the power is off and connect the cvgt MM power connector to
the Model 041 frame. Double check that the connector has been plugged in
correctly; it is keyed to prevent misconnection so it should be straightforward.
Fit the two 4-40 UNC screws supplied to fix the cvgt MM into the Model 041
frame (nylon washers are also supplied).
Only fit and remove modules with the
synthesizer
power off and
disconnected from the mains electricity supply
for your own safety.
Synovatron Electronic Music cannot be held responsible for any damage or
harm caused through incorrect or unsafe use of this module. If in doubt, stop
and check. If you are still unsure of what to do then please contact
Synovatron for advice before proceeding.