
30
Chapter 3: System Maintenance
Replace Power Supply Unit (PSU)
If a PSU or its fan malfunctions, please follow the steps below to replace the malfunctioning PSU.
1
Unplug the power cord from the PSU that is to be replaced.
Note:
By pressing the
Beep Off
button, you can silence the long beep when it sounds.
2
Remove the malfunctioning PSU:
1
On the rear panel, push the lever of the PSU inward as shown.
2
Pull the PSU out of your RX6022sas.
3
Prepare a new PSU. Insert it into the empty slot until you hear a click.
Содержание RX6022sas
Страница 1: ...Expansion Unit RX6022sas Hardware Installation Guide...
Страница 12: ...12 Chapter 2 Hardware Setup 7 Drives are numbered as shown below...
Страница 21: ...21 Chapter 2 Hardware Setup 8 Remove the rail kit from the rack...
Страница 23: ...23 Chapter 2 Hardware Setup 2For 1 HD6500 and 2 RX6022sas HD6500 RX6022sas 1 RX6022sas 2...
Страница 24: ...24 Chapter 2 Hardware Setup 3For 1 HD6500 and 3 RX6022sas HD6500 RX6022sas 1 RX6022sas 2 RX6022sas 3...
Страница 38: ...A VCCI A...