Start up Your Synology NAS

To start up your FS3400:

Connect one end of each power cord to the power ports located on the back of the FS3400 and the other end 

to a power outlet.

Connect at least one LAN cable to one of the LAN ports and the other end to your switch, router, or hub.

Press the power button to turn on the FS3400.

Congratulations! Your Synology NAS is now online and detectable from a network computer.

Содержание NAS FS3400

Страница 1: ...Hardware Installation Guide Synology NAS FS3400 ...

Страница 2: ...9 Install Drives 9 Install Memory Modules 11 Install PCle Add in Cards 13 Install and Remove Rail Kits 15 Expansion Unit Deployment and Topology 17 Start up Your Synology NAS 20 LED Indicator Table 22 Chapter 3 System Maintenance Replace System Fan 23 Replace Power Supply Unit PSU 25 Initial Troubleshooting Guide 25 Chapter 4 Install DSM on Synology NAS Install DSM with Web Assistant 26 Learn More...

Страница 3: ... through all configuration aspects of your FS3400 including the hardware components setup procedures system maintenance and initial troubleshooting instructions Note All images below are for illustrative purposes only and may differ from the actual product Package Contents Main unit x 1 AC power cord x 2 Screws for 2 5 drives x 100 Before You Start 1 Chapter 3 3 ...

Страница 4: ...more information see LED Indicator Table 2 Press to deactivate the beeping sound that is emitted when a malfunction occurs 10 PSU Fan Disposes of excess heat and cools the PSU 11 Console Port This port is reserved for manufacturing use only 12 PCI Express Expansion Slot Supports one PCIe x8 add on network interface card 13 SAS OUT Port Connect Synology Expansion Unit to the SAS OUT port on the rig...

Страница 5: ... Internal Btrfs ext4 External Btrfs ext4 ext3 FAT NTFS HFS exFAT1 Supported RAID Type Basic JBOD RAID 0 RAID 1 RAID 5 RAID 6 RAID 10 Synology RAID F1 Agency Certification FCC Class A CE Class A BSMI Class A HDD Hibernation Yes Scheduled Power On Off Yes Wake on LAN Yes Language Localization Environment Requirement Line voltage 100V to 240V AC Frequency 50 60Hz Operating Temperature 32 to 95 F 0 to...

Страница 6: ... www synology com compatibility for more information Memory Module Model Name Picture Description D4RD 2666 16G 16GB DDR4 2666 ECC Registered DIMM D4RD 2666 32G 32GB DDR4 2666 ECC Registered DIMM PCIe Add in Card Model Name Picture Description E10G18 T2 Dual port 10GbE RJ 45 Network Interface Card E10G18 T1 Single port 10GbE RJ 45 Network Interface Card E10G17 F2 Dual port 10GbE SFP Network Interf...

Страница 7: ...ives RX2417sas 2U 24 bay Rackmount type expansion unit compatible with 2 5 SAS SATA drives Rail Kit Model Name Picture Description RKS1317 Sliding rails Spare Part Model Name Picture Description Disk Tray Type R1 2 5 Drive Tray FAN 80 80 32_6 System Fan Module PSU 500W RP Module_2 Redundant PSU Module PSU 500W RP SET_2 Redundant PSU Set Cage x 1 PSU Module x 2 ...

Страница 8: ...er cord Wipe with damp paper towels Do not use chemical or aerosol cleaners To prevent the unit from falling over do not place on carts or any unstable surfaces The power cord must plug in to the correct supply voltage Make sure that the supplied AC voltage is correct and stable To remove all electrical current from the device ensure that all power cords are disconnected from the power source Risk...

Страница 9: ...tional Accessories section to find out the suitable rail kit for cabinet installation Warning We suggest mounting your Synology NAS on a cabinet before installing any drives since the heavy weight will increase the installation difficulty Install Drives Please follow the steps below for drive installation 1 Open the drive tray a Find the small button located on the bottom side of the drive tray ha...

Страница 10: ... to function properly 4 Push the handle inward to secure the drive tray 5 Push the switch on the drive tray handle to the bottom to lock the drive tray 6 Repeat the steps above to assemble the other drives you have prepared 7 Drives are numbered as shown below Note We suggest installing drives of the same size to optimize drive capacity usage when creating RAID volumes ...

Страница 11: ... B1 Total Memory 16GB 16GB 32GB 32GB 16GB 16GB 32GB 16GB 16GB 16GB 48GB 16GB 16GB 16GB 16GB 64GB 32GB 32GB 64GB 32GB 32GB 32GB 96GB 32GB 32GB 32GB 32GB 128GB Follow the steps below to install check or remove a memory module on your FS3400 To install the RAM module 1 Shut down your FS3400 Disconnect all cables connected to your FS3400 to prevent any possible damage 2 Remove the screw on the back of...

Страница 12: ...mory module with firm and even pressure The retaining clips will snap into position as the module is correctly inserted Note Hold the memory module by its edges and do not touch the gold connectors 4 Put back the rear top cover you lifted in step 2 a Align the hexagons at the side of rear top cover with the slots on the chassis edge and push the rear top cover back in position b Put back and faste...

Страница 13: ...ny components of the motherboard when you cut the cable tie 3 Disengage the memory retaining clips by pushing them outwards and the module will pop out of the slot 4 Follow step 4 of the To install the RAM module section to put back the top cover Install PCle Add in Cards FS3400 provides one PCIe x8 slot for optional add in card expansion allowing network interface cards to be installed To install...

Страница 14: ... inserted Otherwise the network interface card might not be able to function properly d Put back and fasten the screw that you removed in step 3 a so as to secure the newly inserted card d 4 Repeat step 3 to install the other network interface card for your FS3400 5 Put back the rear top cover by following step 4 of the To install the RAM module section ...

Страница 15: ...ion about the rail kit installation please refer to the Quick Installation Guide that comes with the rail kit To install the rail kit 1 To install the rail kit to the rack a Attach the rear end of the rail kit assembly to the rack b Slide the front latch outwards and insert the brackets into the rack holes 2 Extend and pull out the inner rail from the assembly ...

Страница 16: ...f the chassis and slide backward to attach the inner rail 4 With the help of another person carefully align the inner rail to the outer rail assembly 5 Push the chassis towards the rack Use the cage nuts and screws in the rail kit package to secure the chassis to the rack if necessary ...

Страница 17: ...ion with RX2417sas 24 bay and RX1217sas 12 bay providing seamless storage expansion whenever needed This section will guide you through how to connect the expansion units to your Synology NAS To connect RX1217sas RX2417sas with FS3400 1 Connect one end of the expansion cable to the SAS OUT port of your FS3400 and the other to the SAS IN port of RX1217sas RX2417sas Make sure the release band in blu...

Страница 18: ...expansion cable while the host device is still powered on Doing so may result in data loss 3 Press the power button on the front panel to power on your FS3400 The expansion unit ID of RX1217sas RX2417sas connected to FS3400 will be displayed in sequence on the back panel Note Even with the Synology NAS and expansion unit s powered on you can still expand with one or more expansion unit if needed T...

Страница 19: ...he power ports located on the back of the FS3400 and the other end to a power outlet 2 Connect at least one LAN cable to one of the LAN ports and the other end to your switch router or hub 3 Press the power button to turn on the FS3400 Congratulations Your Synology NAS is now online and detectable from a network computer ...

Страница 20: ...inking Network active Off No network Rear 1GbE LAN on right side of jack Green Static 1 Gbps connected Orange Static 100 Mbps connected Off 10 Mbps connected No network Rear 10GbE LAN on left side of jack Green Static Network connected Blinking Network active Off No network Rear 10GbE LAN on right side of jack Green Static 10 Gbps connected Orange 1 Gbps connected Off No network Note This table is...

Страница 21: ...f a system fan malfunctions please see the instructions below to open the case of FS3400 and replace the malfunctioning fan 1 Press the small buttons located on the sides of the FS3400 2 Lift to remove the fan cover 3 Fans are numbered as indicated below ...

Страница 22: ...22 Chapter 3 System Maintenance 4 Find the malfunctioning fan Lift the fan upward to remove it 5 Prepare a new fan and slide it into the FS3400 Make sure the fan is aligned properly as illustrated below ...

Страница 23: ... What can I do to troubleshoot NAS connection problems What is the width of my Synology NAS server Hard Disk Drive How to choose the right HDD for my Synology NAS How to diagnose drives health status when receiving bad sector warning How to fix hard drive failure and retrieve the data from your hard drives Memory Are there any requirements for installing or expanding system memory capacity How can...

Страница 24: ...ill be launched in your web browser It will search for and find the Synology NAS within the local network The status of the FS3400 should be Not Installed 5 Click Connect to start the setup process and follow the onscreen instructions Note 1 The Synology NAS must be connected to the Internet to install DSM with Web Assistant 2 Suggested browsers Chrome Firefox 3 Both the Synology NAS and the compu...

Страница 25: ...ly permitted by applicable law notwithstanding this limitation d adapt modify alter translate or create any derivative works of the Software e remove alter or obscure any copyright notice or other proprietary rights notice on the Software or Product or f circumvent or attempt to circumvent any methods employed by Synology to control access to the components features or functions of the Product or ...

Страница 26: ...Products Any such transfer or assignment in violation of the foregoing restriction will be void Section 17 Applicable Law Unless expressly prohibited by local law this EULA is governed by and construed in accordance with the laws of the country in accordance with which Synology Inc was organized without regard to any conflict of law principles to the contrary Section 18 Dispute Resolution Any disp...

Страница 27: ...pgrades to such software Section 2 Warranty Period a Warranty Period The warranty period commences on the purchase date shown on the purchase receipt or invoice to be presented by Customer and ending 1 five years after such date for Category I Products 2 three years after such date for Category II lll Products 3 two years after such date for Category IV Products 4 one year after such date for Cate...

Страница 28: ...rwise fails to conform to the Product specifications and such failure is attributable to causes not within or under Synology s control Further the foregoing warranties will be void if 1 Customer disassembles the Product except as authorized by Synology 2 Customer fails to implement any correction modification enhancement improvement or other update made available to Customer by Synology or 3 Custo...

Страница 29: ...U N Convention on Contracts for the International Sale of Goods or any successor thereto does not apply 5 5 Dispute Resolution Any dispute controversy or claim arising out of or relating to this Warranty the Product or services provided by Synology with respect to the Product or the relationship between Customers residing within the United States and Synology will be resolved exclusively and final...

Страница 30: ...force and effect 5 9 Entire Agreement This Warranty constitutes the entire agreement and supersedes any and all prior agreements between Synology and Customer related to the subject matter hereof No amendment modification or waiver of any of the provisions of this Warranty will be valid unless set forth in a written instrument signed by the party to be bound thereby Powered by TCPDF www tcpdf org ...

Страница 31: ...ies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ...

Страница 32: ...equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropria...

Страница 33: ...この装置は クラス A 機器です この装置を住宅環境で使用すると電波妨 害を引き起こすことがあります この場合には使用者が適切な対策を講ずる よう要求されることがあります VCCI 一 A ...

Отзывы: