SYNETICA enLink OAQ 

Quick Start Guide Rev 1.5 

 

 

  

 
 

Quick Start Guide  

 
 

enLink OAQ 

Wireless Outdoor Air Quality Monitor 

 

 

LoRa long range wireless 

 

Battery or externally powered 

 

Built in sensor options for: 

 

Temperature (°C) 

 

Humidity (%RH) 

 

Barometric Pressure (Pa) 

 

Volatile 

Organic Compounds (VOC’s)

 

 

EPA Air Quality Index (AQI)  

 

Carbon Dioxide (CO

)* 

 

Sound (dB)* 

 

Particles PM 1, 2.5, 4, 10* 

 

Ozone (O

3

)* 

 

One additional gas from CH

2

O (Formaldehyde), CO, NO

2

, H

2

S, SO

2

, O

2

. * 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature 

Humidity 

VOC’s

 

Pressure 

CO

2

 

Sound 

Particles  

Ozone 

 Additional Gases 

The enLink OAQ wireless Air Quality Monitor is a precision instrument 
which accurately measures up to 10 key environmental parameters 

including Temperature, Humidity,  VOC’s, Carbon Dioxide, Particulate 

Matter (PM1, PM 2.5, PM4 & PM10), EPA AQI (based on O3 and NO2), 
Sound Level, Barometric Pressure, Ozone, Formaldehyde, Carbon 
Monoxide, Nitrogen Dioxide, Hydrogen Sulphide, Sulphur Dioxide and 
Oxygen. 
 
 
Readings are transmitted to the cloud using long range LoRa wireless, 
where the data can be displayed and analysed.   

A built in USB port allows all parameters including air quality data, 
wireless signal strength and wireless network configuration to be 
viewed and set using simple menus via any USB enabled host such as 
a PC or Mac. 

 

 

Features 

 

Multiple sensor options* 

 

LoRa long range wireless 

 

Frequency Range 863-870MHz* 

 

Frequency Range 902-928MHz* 

 

Up to +18dBm Tx Power  

 

Built in USB port for configuration 

 

Battery or externally powered  

 

CE / FCC compliant 

 

RoHS compliant 

 

Made in the UK 

 

*

Model dependent 

Содержание enLink OAQ

Страница 1: ... including Temperature Humidity VOC s Carbon Dioxide Particulate Matter PM1 PM 2 5 PM4 PM10 EPA AQI based on O3 and NO2 Sound Level Barometric Pressure Ozone Formaldehyde Carbon Monoxide Nitrogen Dioxide Hydrogen Sulphide Sulphur Dioxide and Oxygen Readings are transmitted to the cloud using long range LoRa wireless where the data can be displayed and analysed A built in USB port allows all parame...

Страница 2: ... secure and flexible method The OTAA configuration requires the following parameters to be correctly set DevEUI End device Identifier It is unique for every device and is set at device manufacture AppEUI JoinEUI Application Identifier Used to identify the end application AppKey Application key Used to create the session keys Note In LoRaWAN 1 1 AppEUI was renamed to JoinEUI For many applications S...

Страница 3: ...present in the QR code The DevEUI can be used to identify the device once joined to the network To power the device ON first remove the sensor cartridge from the housing by removing the three screws from the bottom of the unit Once the sensor cartridge is removed install batteries and slide the power switch to BATT or apply external power 12V 24V DC to the unit and slide the power switch to EXT Mo...

Страница 4: ...enLink device will send a Join request message to the gateway The Status LED will blink RED as shown below whilst the Join process is taking place Depending on factors such as signal strength RF interference etc the Join process may take several seconds to complete BATT EXT USB Connector ...

Страница 5: ...Rev 1 5 Blinking Red LED Attempting Join When the device has successfully joined the network the Mode LED will blink GREEN for several seconds to show that the Join has been completed The LED s will then switch off to conserve the batteries ...

Страница 6: ...cally once the enLink OAQ unit is in wireless range and powered on The DevEUI is always set at device manufacture and is unique The device AppEUI and AppKey can easily be set via the USB connection as detailed below Once the sensor cartridge is removed connect a micro USB cable to the enLink unit There are two USB connectors on the enLink OAQ so be sure to connect to the correct USB port USB2 as s...

Страница 7: ...yed DevEUI in the screen below this is 1e51 enLink logon screen The screen below will show with the enLink Main Menu options Enter Q to enter the Quick Start Menu enLink Main Menu The Quick Start Menu contains only the parameters that normally need to be configured to setup the device and join the LoRa network From the Quick Start Menu you can change the AppEUI and AppKey Quick Start Settings Menu...

Страница 8: ...ich you can then edit Press Enter when the key is correctly entered to return to the Quick Start Settings Menu AppKey setting Press X from the Quick Start Settings Menu to return to the enLink Main menu The header will show Reboot Required as shown below The new key settings will not take effect until the enLink device is restarted Enter r to reboot followed by OK The device will restart with the ...

Страница 9: ...elow will show The sensors will vary according to the enLink OAQ model and the installed sensors Live Display Configuration Menu The enLink OAQ configuration menu allows you to view current sensor readings and also to change various functions of their behaviour such as calibration data To enter the Configure Device menu press c from the main menu A screen similar to the one below will show The exa...

Страница 10: ...SYNETICA enLink OAQ Quick Start Guide Rev 1 5 ...

Страница 11: ...ensor has read is not within a sensible range of the target concentration level So if the target concentration level is 400 the Out of bounds value is 50 and the minimum reading is 451 or more the calibration routine is ignored I Initial Interval It is possible for the first auto calibration to take place more quickly than the regular auto calibration events This can be useful to stabilise the rea...

Страница 12: ...nded setting for most applications The fan run time may be extended for certain applications however this will have an impact on the battery life of the unit The particulate sensor has a self cleaning function which runs the fan at high speed to clean away any dust build up in the measurement chamber By default this cleaning cycle operates every 7 days but may be changed if required Reducing the c...

Страница 13: ...teries in an explosive gas atmosphere When installing batteries do not snag the battery terminal on the clip or the battery may be damaged Do not apply excessive force Do not drop Dropping the battery may cause damage If a battery is dropped do not install the dropped battery into the unit Dispose of dropped battery promptly per local regulations or per the battery manufacturer s recommendations G...

Страница 14: ... from any exhaust ducts or flues Mounting guidelines for OAQ Units Do not expose to direct sunlight Do not mount on facades with a lot of ascending heat Do not attach to walls in front of a chimney Do not mount on eaves or a balcony Do not place over windows Do no mount over ventilation shafts Do not paint over sensors Mount sensors in an accessible location to allow easy inspection and maintenanc...

Страница 15: ...cket using suitable pan head screws and then slide the OAQ onto the screws Weight without batteries 180g Weight with batteries 250g Technical Support For technical assistance please visit the downloads section of our web site at www synetica net or email us at support synetica net ...

Отзывы: