3. The water level sight glass for the steam tank is located on the right side of the machine. As the tank
fills, the water level will rise in the sight glass and will automatically stop when the preset level is
reached.
4. To bleed the air from each brew group, use the electronics override button on the right side of the
brew group. Leave it ON until all the air has escaped and water starts flowing.
5. Make sure the water level in the sight glass reads at least ½ full and then turn the heating element
breaker to the ON or (1) position.
6. To adjust the pump pressure, activate the pump infusion by turning on a Volume button on the
keypad.
7. Locate and read the pump pressure / brew gauge.
8. Set the pump pressure to 9 Bar. To do this, locate the pump adjusting screw on the right side of the
brass pump housing. Loosen the lock nut and turn screw with a screwdriver.
•
Clockwise to INCREASE pressure
•
Counterclockwise to DECREASE pressure
9. Please allow at least ½ hour of “warm up” time before using your Sabre espresso machine to brew
shots or steam milk. The steam gauge should read a minimum of 1.1 Bar.
Unplugging EMC Compliant Machines
(C-Tick for Australia and NZ, CE for Europe)
To comply with EMC (Electromagnetic Compatibility) regulations, Synesso is required to install a capacitor
in the electronics box across the main power IN. To avoid an electric shock from the charge held in the
capacitor, leave the electronics ON/OFF red rocker switch in the ON position when unplugging the machine.
When the electronics “go dark” or OFF, the charge has dissipated.