Jumper Setting for SY-10/xR
Connect wires
Below please find a detailed list of the SY-10 wire
connections:
Terminal block = P2
* When JP9 is [1-2] [3-4] ON, SEN1.2=GND
When JP9 is [2-3] ON, SEN1.1=Sensor AC
Terminal block = P3
Note: In this model only the voltage, bell and communi-
cation signals are active.
Specifications
Man Machine interface:
• LED indicators for power ON
• Keypad
• LED Bi-Color
• Bell button
Output signal: negative logic max. 10mA
Power supply: 12Vdc @ 120mA
Magnetic reader (bar-code- optional)
Output in RS232 protocol
Communication:
Baud rate is 9600
Data bits: 8
Parity: None
Mechanical Features
• Dimensions: 9 X 14 X 4.5
• Weight: 200gr
• Operating temperature: +5
0
to +50
0
C
• Relative humidity: 90%, non-condensing
Models
SY-10/MR - Magnetic track II reader, terminal block output
SY-10/PR- Magnetic track I reader, terminal block output
SY-10/BR- Bar-code reader, terminal block output
SY-10/PRX/R- Proximity reader, terminal block output
SY-10/xR
RS-232 Transmission
Reader
Condensed Instructions
Cat no. 650502 (SY10R-222-01)
Jumper
Description
Pos. 1-2
Pos. 2-3
Default
JP1
Programming/
normal operation
Normal
operation
Programming Normal
operation
JP2
Barcode/magnetic Magnetic
Barcode
per reader
JP4
Tamper switch
ON
OFF
ON
Wire
no.
Wire
Name
Wire function
P2.1
COM
Relay Connection
P2.2
SEN1.1
Door sensor connection
P2.3
NC
Relay normally closed
P2.4
SEN1.2
*
P2.5
NO
Relay normally open
P2.6
BL2
Bell
Wire
no.
Wire
Name
Wire function
P3.1
BL1
Bell (1)
P3.2
12V
P3.3
Alarm
Not available
P3.4
Ground
P3.4
TX
Transmit Data (RS-232)
P3.5
RX
Receive Data (RS-232)
P3.6
-TXRX
RS-485
P3.6
+TXRX RS-485
Control LED
Power LED
Communication cable