SPECIFICATIONS 

Dim Control Max Load: 10 mA Source/Sink

Radio Frequency: 2.4 GHz (IEEE 802.15.4)

RF Transmission Output Power: +20dBM

Operating Temperature: -40 to +85 C

Operating Humidity: 10 to 90%, non-condensing

DALI-2: Limited to 

6

 LED Drivers

Wire Size: 18 AWG, 8” Wires, UL1316, 600V

Dimensions: 2.25” L x 2.0” W x .3” H

(57 x 50.8 x 7.6 mm) 

CAUTION 

DIM10-087-06-FW controllers must be installed in 
accordance with national, state, and local electrical 

codes and requirements. 

DESIGN CONSIDERATIONS 

Below are some recommendations for successful 
dimming using the DIM10-087-06-FW. The dimming 

control wires are referenced as Dim+ and Dim-.  The 

dimming signals have a Maximum voltage of 10V DC. 

Do not ground the DIM- wire to chassis ground;
this is a return signal and is critical for proper

dimming.

Route dimming wires away from AC lines if

possible.

For DALI applications – Maximum of 8 LED Drivers

supported per controller.

Do not mount to a heatsink or to a LED driver.

When installing the DIM10-087-06-FW into an
enclosure, consideration of the internal antenna

position and interference is required in order to
provide the most optimum wireless signal

strength. Prior to permanently mounting it, make
sure the antenna is free of any metal objects

within 12 in. of the antenna.

 

 

INSTALLATION INSTRUCTIONS 

WARNING: TO AVOID FIRE, SHOCK, OR 
DEATH: TURN OFF POWER

 AT CIRCUIT 

BREAKER OR FUSE AND VERIFY THAT POWER IS 

OFF BEFORE WIRING! 

MOUNTING 

1.

Place the controller in desired location and secure
it using a #4 or M3 sized screw using the mounting

hole located in the center of the DIM10-087-06-

FW.

WIRING THE DIM10-087-06-FW 

CONTROLLER

  

Note: Unless specified, the connections to a 
standard Dim to Off LED driver and the DALI 2 

LED driver are the same. 

2.

Connect the POWER (BROWN) wire of the DIM10-
087-06-FW to the 5-24V DC Aux output from the

LED driver.

3.

Connect the DIM- and DALI- (GRAY/WHITE

STRIPE) wires of the DIM10-087-06-FW to the
COMMON/DALI- or COMMON/DIM- based on the

LED driver you have.

 

 
 

CONNECTING SENSORS 

Note: Steps 4-7 are for adding sensors to the 
DIM10-087-06-FW controller; if you are not 

connecting sensors skip this section. 

 

There are two sensor inputs on the DIM10-087-06-FW 

designed for low powered (24V DC) type sensors.

 

The 

SENSOR A (YELLOW) 

wire is used to

connect sensor A.

The 

SENSOR B (ORANGE) 

wire is used to

connect sensor B.

4.

Connect the sensor power wire to the AUX out on

the LED driver (the LED driver powers the sensor).

5.

Connect the sensor Common to the
COMMON/DALI- or COMMON/DIM- based on the

LED driver you have.

6.

Connect the 

SENSOR A (YELLOW) wire or the

SENSOR B (ORANGE) wire 

of the DIM10-87-06-FW

controller to the sensor CTRL/Control wire.

7.

If you are using more than one sensor then

duplicate the installation as described above.

(See Figures 1 AND 2) 

CONNECTING THE DIMMING CIRCUIT 

Note: Steps 8-10 are for connecting up to a 
Standard Dim to Off LED driver; if you are using a 

DALI 2 LED driver skip to steps 11-13. 

8.

Connect the DIM+ (PURPLE) wire from the DIM10-

087-06-FW to the DIM+ wire on the LED driver.

9.

Connect the DIM- (GRAY/WHITE STRIPE) wire
from the DIM10-087-06-FW to the COMMON/DIM- 

wire on the LED driver.

10.

Cap the unused DALI+ (PURPLE/WHITE STRIPE)

wire.
(See Figure 1)

DIM10-087-06-FW Controller

 

Load Ratings: 700mW @ 5 to 24V DC 

Operating Temperature: -40 to +85 C / Operating Humidity: 10 to 90%, non-condensing 

WARNING AND CAUTIONS: 

TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER

 AT CIRCUIT BREAKER

OR FUSE AND TEST THAT POWER IS OFF BEFORE INSTALLING!

PROPER GROUNDING REQUIRED TO AVOID STATIC DISCHARGE WHICH
CAN DAMAGE CONTROLLERS DURING INSTALLATION.

 

INSTALLATION GUIDE 

 

WARNING AND CAUTIONS:

 

If you are unsure about any part of these instructions, consult an electrician; all
work should be performed by qualified personnel.

Disconnect power at circuit breaker or fuse when servicing, installing or removing
fixture or changing lamps.