WARNING

TO REDUCE THE RISK OF FIRE OR 

ELECTRICAL SHOCK, DO NOT EXPOSE THIS 

APPLIANCE TO RAIN OR MOISTURE

 

 

● ALWAYS disconnect your entire system from the AC mains before cleaning any component. The product 
frame (SFR18 or SFR04) must be terminated with three-conductor AC mains power cord that includes an 

earth ground connection. To prevent shock hazard, all three connections must always be used. 
● NEVER use flammable or combustible chemicals for cleaning components. 
● NEVER operate this product if any cover is removed. 
● NEVER wet the inside of this product with any liquid. 
● NEVER pour or spill liquids directly onto this unit. 
● NEVER block airflow through ventilation slots. 
● NEVER bypass any fuse. 
● NEVER replace any fuse with a value or type other than those specified. 
● NEVER attempt to repair this product. If a problem occurs, contact your local Axon distributor. 
● NEVER expose this product to extremely high or low temperatures. 
● NEVER operate this product in an explosive atmosphere. 
 

Warranty:

 Axon warrants their products according to the warranty policy as described in the general terms. 

That means that Axon Digital Design BV can only warrant the products as long as the serial numbers are not 

removed. 

 

Copyright © 2001 – 2006 AXON Digital Design B.V. 

Date created: 

 

16-10-02 

Date last revised: 

09-10-13 

 

Axon, the Axon logo and Synapse are trademarks of Axon Digital Design B.V. 

 

This product complies with the requirements of the product family standards for audio, video, audio-visual 

entertainment lighting control apparatus for professional use as mentioned below. 

 

 

 
EN60950 
EN55103-1: 1996 
EN55103-2: 1996 
 

 
Safety 
Emission 
Immunity 

 

 

Axon Digital Design        

DAD0809 

 

Tested To Comply 

With FCC Standards 
 

FOR HOME OR OFFICE USE 
 

 

 
This device complies with part 15 of the FCC Rules 
Operation is subject to the following two conditions: 
(1) This device may cause harmful interference, and 
(2) This device must accept any interference received, including 
interference that may cause undesired operation. 
 

 

 

Содержание DAD08

Страница 1: ...___________________________________________ DAD08 09 Digital Audio Distribution Amplifier...

Страница 2: ...Lange Wagenstraat 55 NL 5126 BB Gilze The Netherlands Phone 31 161 850 450 Fax 31 161 850 499 E mail Info axon tv Web www axon tv TECHNICAL MANUAL DAD08 DAD09 Digital Audio Distribution Amplifier...

Страница 3: ...o extremely high or low temperatures NEVER operate this product in an explosive atmosphere Warranty Axon warrants their products according to the warranty policy as described in the general terms That...

Страница 4: ...Quick Start When powering up Default settings Changing parameters and settings Front Panel Control Example of changing parameter using Front Panel control Synapse Setup Software Menu Structure Example...

Страница 5: ...ocal control panel is also used to back up and restore card settings Please refer to the rack controller manuals RRCxx RRSxx ERCxxx and ERSxxx for a detailed description of the local control panel the...

Страница 6: ...ature failure from components mounted on the board Placing the card The Synapse card can be placed vertically in an SFR18 frame or horizontally in an SFR04 and SFR08 frame Locate the two guide slots t...

Страница 7: ...ers The front panel controls or the Cortex Software can be used to change settings An overview of the settings can be found in chapter 5 6 and 7 of this manual Front Panel Control Front Panel Display...

Страница 8: ...to indicate that the SFS10 Settings menu item SDI Format has been selected and shows that it current setting is Auto Pressing the selects the settings item shown in this example SDI Format Pressing or...

Страница 9: ...address giving access to each module its menus and adjustment items Cortex has access to data contained within the Synapse module and displays it on a GUI The software has an intuitive structure foll...

Страница 10: ...96 kHz are indicated Signal Status Indication Signal status and error messages included in the audio data format are decoded and displayed I O Flexibily The DAD08 and DAD09 offer a wide range of inpu...

Страница 11: ...tor panel similar to the BPL01 with a back up facility to connect J1 with J4 in a card or power failure situation Also an all D Sub version can be used The BPL05D Fiber backplane with unbalanced In Ou...

Страница 12: ...control and Cortex software Validity bit This setting sets the validity bit in the AES audio stream The validity bit is 0 if the audio sample word is suitable for conversion to an analog audio signal...

Страница 13: ...the following status No Error The digital audio signal has no errors Validity Bit High Indicates that the validity bit for a previous sample was high since the last clearing of the error codes CRC Er...

Страница 14: ...the announcement of status changes on off 0 off other on Input Input can be selected between 0 255 0 no event 1 255 is the priority setting What information is available in an event The message consis...

Страница 15: ...ined for the DAD08 09 are Event Menu Item Tag Description Announcements 0 or NA 0 or NA Announcing of report and control values Input 01hex INP_LOSS 81hex INP_RETURN primary input lost or returned The...

Страница 16: ...cards the Error LED is not used Input LED This LED indicated the presence of a valid AES EBU digital audio signal on the input Connection LED This LED illuminates after the card has initialised The L...

Страница 17: ...8 09 INTERNAL SYNAPSE BUS Rack controller P AES EBU OUT 1 DAD08 only AES EBU IN AES EBU DECODER AES EBU OUT 2 AES EBU OUT 3 AES EBU OUT 4 AES EBU OUT 5 AES EBU OUT 6 AES EBU OUT 7 AES EBU OUT 8 STATUS...

Страница 18: ...1 BPL05 and BPL05D BPL01 BPL05 BPX01 BPL05D Fiber BPL01T_FC PC BPL01T_SC BPL01R_FC PC and BPL01R_SC DAD 08 AES EBU I N A E S E B U O U T 8 7 6 5 3 4 2 1 4 7 DAD 08 8 6 5 A E S E B U O U T 1 3 2 A E S...

Страница 19: ...17 BPL05D...

Отзывы: