3. Parts Breakdown (Model Numbers Ending in TRMTC)

5. Installation - Adjust Packing Nut 

(Model Numbers Ending in TRMTC)

1) Turn hot and cold supplies on.  Valve will not operate unless both hot and cold water supply pressures are on.

2)  Place handle over flow control spindle.

3)  Tighten packing nut for positive frictional resistance as handle is rotated from shut-off position across adjustment range.

6. Installation - Setting Limit Stop Screw 

(Model Numbers Ending in TRMTC)

1) Turn hot and cold supplies on.  Valve will not operate unless both hot and cold water supply pressures are on.

2)  Place handle on flow control spindle and open valve to maximum desired temperature.

3)  Turn limit stop screw clockwise until it seats.

     WARNING:

  Failure to adjust limit stop screw properly may result in serious scalding.

The temperature limit stop screw limits valve handle from being turned to maximum position resulting in excessive hot 

water discharge temperatures.

4. Installation - Remove Test Cap 

(Model Numbers Ending in TRMTC)

1)  Check for leaks around the valve assembly and all pipe 

fittings.

Flow control spindle (TA-10) and cap assembly (T-12A) will 

come factory assembled for all model numbers ending in 

TRMTC

.  When ready to remove Test Cap and install trim, 

follow the instructions below:

2)  Remove test cap from valve (FIGURE 4.1).

3)  If system is dirty, flush valve. 

4)  Thread flow control spindle and cap assembly into valve 

body.  Turn clockwise to secure to valve (FIGURE 4.2).

FIGURE 4.1

FIGURE 4.2

LIMIT STOP 

SCREW

2

1

PACKING 

NUT

FIGURE 3

Replacement Parts

Item

Description

Part Number

1

Cap Assy.

T-12A

2

Flow Control Spindle

TA-10

IMPORTANT:

  Model numbers ending in 

TRMTC

 

coordinate with Temptrol pressure balancing valves 

ordered with Test Cap.  The Test Cap is used to 

allow pressurization of system.  

Do not

 remove 

test cap from valve during wall construction, 

installation of valve or pressurization of system.

  WARNINGS:

1.  Test cap rated for pressure testing up to 200 

psi maximum.  

DO NOT

 exceed 200 psi while 

pressure testing valve body.

2.  Do not expose valve with test cap to heat 

for longer than 2 minutes when soldering 

copper tubing.  Doing so may damage the 

internal components of the valve and will 

void the product warranty.

3.  Ensure test cap is re-torqued to 

30 lb-ft 

after 

soldering valve body.

Содержание Winslet S-5100-TRM

Страница 1: ...S5101TRMTC Shower Trim S5102TRMTC Tub Shower Trim S5104TRMTC Tub Hand Shower Trim S5108TRMTC Shower Hand Shower Trim S 5100 TRM S5100TRMTC S 5101 TRM S5101TRMTC S 5102 TRM S5502TRMTC S5108TRM S5108TR...

Страница 2: ...o change without notice Phillips Screwdriver Adjustable Wrench Safety Glasses Thread Seal Tape Drill Allen Wrench 3mm FIGURE 1 2 Dimensions Measurements A 2 1 2 64 mm B 12 305 mm C Male 1 2 NPT thread...

Страница 3: ...e assembly and all pipe fittings Flow control spindle TA 10 and cap assembly T 12A will come factory assembled for all model numbers ending in TRMTC When ready to remove Test Cap and install trim foll...

Страница 4: ...ll threaded connections FIGURE 7 A B C J K N L M G G H F E D I EF 109 Order in line vacuum breaker EF 109 for hand shower systems without dual checks 7 Parts Breakdown Replacement Parts Item Descripti...

Страница 5: ...E 8 4 5 Install handle to shower valve Secure with set screw FIGURE 8 5 FIGURE 8 1 FIGURE 8 2 FIGURE 8 3 1 Attach arm and flange to shower pipe Turn clockwise to tighten FIGURE 9 1 2 Install showerhea...

Страница 6: ...tighten FIGURE 10 4 4 Attach large end of hand shower hose to hand shower wand Turn clockwise to tighten FIGURE 10 5 1 Install wall cradle flange to pipe fitting Turn clockwise to secure FIGURE 10 1...

Страница 7: ...valve in hot position FIGURE 11 3 FIGURE 11 1 FIGURE 11 2 FIGURE 11 3 12 Operation VersaFlex Diverter Control Turn volume control handle clockwise to increase volume Turn volume control handle counter...

Страница 8: ...micals including lead which is known to the state of California to cause cancer birth defects or other reproductive harm For more information go to www P65Warnings ca gov 14 Troubleshooting Chart Prob...

Отзывы: