TROUBLE SHOOTING CHART

Symmons Industries, Inc.  

  31 Brooks Drive  

  Braintree, MA  02184

(800) 796-6667, (781) 848-2250  

  Fax (800) 961-9621, (781) 664-1300    

Website:  www.symmons.com  

  Email: c u s t o m e r s e r v i c e @ s y m m o n s . c o m

©2007, 2008 Symmons Industries, Inc.   Printed in U.S.A.   

  ZV-409  

    0 9 2 9 0 9

SERVICE INSTRUCTIONS

Changing the mixer 

1. Close the water inlet(s).
2. Remove Housing screw (SF-152).
3. Remove Handle screw (SF-155), handle (SF-154), 

handle limit stop (SF-156), housing and mixer
(SF-162).

4. Install new mixer reversing steps above.

Changing solenoid valve 

1. Close the water inlet(s).
2. Remove Housing screw (SF-152).
3. Remove Handle screw (SF-155), handle (SF-154), 

handle limit stop (SF-156), housing and solenoid valve 
(SF-150).

4. Install new solenoid valve reversing steps above.

Cleaning or changing the solenoid valve

membrane 

1. Close the water inlet(s).
2. Remove Housing screw (SF-152).
3. Remove Handle screw (SF-155), handle (SF-154), 

handle limit stop (SF-156), housing and solenoid valve 
membrane  (SF-151).

4. Clean the membrane (SF-151) or if necessary replace 

with a new one reversing the steps above.

Changing the battery (Lithium 2CR5 6V)
(See fi gure 1)

A blinking signal light on the sensor indicates that the 
battery needs to be changed.
1. Close the water inlet(s).
2. Remove Housing screw (SF-152).
3. Remove Handle screw (SF-155), handle (SF-154), 

handle limit stop (SF-156) and housing.

4. Remove battery holder and replace battery as shown 

reversing steps above.

Changing the sensor (See fi gure 2)

Note: Special tool required

1. Close the water inlet(s).
2. Remove Housing screw (SF-152).
3. Remove Handle screw (SF-155), handle (SF-154), 

handle limit stop (SF-156) and housing.

4. Remove battery holder, clip, and sensor (SF-147) as 

shown and install new sensor reversing steps above.

Problem

Cause

Solution 

(Follow service instructions)

Water fl ow from the outlet does not 
stop.

The sensing range is too low or the 
solenoid valve is damged.
Solenoid valve membrane is dirty.

Check that the photocell is clean.
Replace solenoid valve.
Clean the solenoid valve mem-
brane.

Water fl ow is low and weak.

Supply stop(s) not fully opened.
The Litter fi lter(s) or aerator is 
clogged.

Open supply stop(s).
Clean  the litter fi lter(s) and aerator.

No water comes out of the faucet.

Faucet not recieving water.
The solenoid valve is damaged.
Power failure.
The sensor is covered or damaged.
Battery not installed correctly.

Check the water supply to the 
faucet.
Replace solenoid valve.

Clean or replace sensor.
Check battery installation.

Sensor eye is blinking.

Ultra-Sense’s visible diagnostic 
signal is activated indicating low 
battery voltage.

Replace battery Lithium 2CR5 6V.

Temperature can’t be adjusted.

Mixer is damaged.
Litter fi lters are dirty.

Clean or replace the mixer.
Clean the litter fi lter(s).